{"product_id":"cummins-c150d6d-150kw-agriculture-generator-a061t474","title":"Cummins C150D6D 150kW Agriculture Diesel Generator 120\/240V 1-Phase | A061T474","description":"\u003ch2\u003eCummins C150D6D 150kW Agricultural Diesel Generator\u003c\/h2\u003e\n\n\u003cp\u003eProtect essential farm operations during utility outages with the \u003cstrong\u003eCummins C150D6D 150kW Agricultural Diesel Generator\u003c\/strong\u003e. Cummins part number \u003cstrong\u003eA061T474\u003c\/strong\u003e is a factory-configured agricultural standby generator designed for farms, dairy facilities, poultry houses, livestock operations, irrigation systems, grain facilities, greenhouses, cold storage and other agricultural applications requiring reliable 120\/240-volt single-phase power.\u003c\/p\u003e\n\n\u003cp\u003eThis heavy-duty diesel generator delivers \u003cstrong\u003e150kW of standby power\u003c\/strong\u003e at \u003cstrong\u003e120\/240V single phase\u003c\/strong\u003e. It combines a Cummins QSB7-G5 industrial diesel engine, a brushless four-pole alternator, PowerCommand 1.1 electronic controls and an \u003cstrong\u003e800-amp main circuit breaker\u003c\/strong\u003e in an open-skid agricultural configuration.\u003c\/p\u003e\n\n\u003cdiv style=\"padding:16px; margin:20px 0; border:2px solid #b42318; background:#fff5f5;\"\u003e\n  \u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eImportant Agricultural Configuration Notice\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eCummins A061T474 is an open generator set with no weather enclosure, no sound enclosure and no onboard diesel fuel tank.\u003c\/strong\u003e It requires a properly designed generator building or separately purchased enclosure, an external diesel fuel system, starting batteries, transfer equipment and professional installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003e150kW Standby Power for Agricultural Operations\u003c\/h2\u003e\n\n\u003cp\u003eModern farms rely on electrical power for ventilation, refrigeration, irrigation, milking systems, feeding equipment, grain handling, water pumps, lighting and environmental controls. A power outage can quickly place livestock, crops, stored products and production schedules at risk.\u003c\/p\u003e\n\n\u003cp\u003eThe Cummins C150D6D is engineered to supply dependable emergency standby power and respond rapidly as electrical loads change. Its 120\/240V single-phase configuration is designed for larger farms and rural facilities with high-capacity single-phase electrical service.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e150kW emergency standby power rating\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase electrical output\u003c\/li\u003e\n  \u003cli\u003e60 Hz operating frequency\u003c\/li\u003e\n  \u003cli\u003eApproximately 625 amps at full standby output\u003c\/li\u003e\n  \u003cli\u003e800-amp factory main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCummins QSB7-G5 industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e6.7-liter inline six-cylinder engine\u003c\/li\u003e\n  \u003cli\u003eTurbocharged and charge-air-cooled design\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM rated engine speed\u003c\/li\u003e\n  \u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n  \u003cli\u003eAutomatic remote-start and stop capability\u003c\/li\u003e\n  \u003cli\u003eBattle Short Mode\u003c\/li\u003e\n  \u003cli\u003eFlexible exercise scheduling\u003c\/li\u003e\n  \u003cli\u003eIntegrated generator protection and diagnostics\u003c\/li\u003e\n  \u003cli\u003eBrushless four-pole alternator\u003c\/li\u003e\n  \u003cli\u003eLow-reactance 2\/3-pitch alternator windings\u003c\/li\u003e\n  \u003cli\u003eHigh-ambient liquid-cooling system\u003c\/li\u003e\n  \u003cli\u003eOpen-skid agricultural configuration\u003c\/li\u003e\n  \u003cli\u003eNo enclosure or diesel fuel tank included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCummins QSB7-G5 Industrial Diesel Engine\u003c\/h2\u003e\n\n\u003cp\u003eThe C150D6D is powered by the \u003cstrong\u003eCummins QSB7-G5\u003c\/strong\u003e, a rugged 6.7-liter, inline six-cylinder diesel engine engineered for stationary power-generation applications. Its heavy-duty cast-iron construction and four-cycle design provide dependable performance and fast response to changing agricultural loads.\u003c\/p\u003e\n\n\u003cp\u003eThe engine uses turbocharging and charge-air cooling to support efficient combustion and consistent power output. Its 1,800 RPM operating speed is suited for stationary standby-generator service and extended utility outages when operated and maintained according to Cummins requirements.\u003c\/p\u003e\n\n\u003ch3\u003eEngine Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins QSB7-G5 diesel engine\u003c\/li\u003e\n  \u003cli\u003e6.7-liter displacement\u003c\/li\u003e\n  \u003cli\u003eInline six-cylinder configuration\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty cast-iron construction\u003c\/li\u003e\n  \u003cli\u003eFour-cycle industrial design\u003c\/li\u003e\n  \u003cli\u003eTurbocharged and charge-air cooled\u003c\/li\u003e\n  \u003cli\u003eLiquid-cooled operation\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM rated speed\u003c\/li\u003e\n  \u003cli\u003e17.2:1 compression ratio\u003c\/li\u003e\n  \u003cli\u003e17.4-liter lubricating-oil capacity\u003c\/li\u003e\n  \u003cli\u003eFast response to changing electrical loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePowerCommand 1.1 Electronic Control System\u003c\/h2\u003e\n\n\u003cp\u003eThe integrated \u003cstrong\u003eCummins PowerCommand 1.1\u003c\/strong\u003e control system coordinates engine, alternator and generator-protection functions. It supports automatic operation when connected to a compatible automatic transfer switch and provides the monitoring and protection required for critical agricultural standby applications.\u003c\/p\u003e\n\n\u003ch3\u003ePowerCommand Control Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAutomatic remote starting and stopping\u003c\/li\u003e\n  \u003cli\u003ePrecise voltage and frequency regulation\u003c\/li\u003e\n  \u003cli\u003eGenerator output metering\u003c\/li\u003e\n  \u003cli\u003eEngine and generator status monitoring\u003c\/li\u003e\n  \u003cli\u003eAlarm and operating-status messages\u003c\/li\u003e\n  \u003cli\u003eAutomatic shutdown when qualifying faults are detected\u003c\/li\u003e\n  \u003cli\u003eIntegrated generator protection\u003c\/li\u003e\n  \u003cli\u003eSelf-diagnostic capabilities\u003c\/li\u003e\n  \u003cli\u003eNFPA 110 Level 1 control functionality\u003c\/li\u003e\n  \u003cli\u003eProgrammable exercise scheduling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBattle Short Mode\u003c\/h2\u003e\n\n\u003cp\u003eBattle Short Mode allows selected protective shutdowns to be overridden when maintaining electrical power is considered more important than protecting the generator from possible damage.\u003c\/p\u003e\n\n\u003cp\u003eThis function can be valuable during agricultural emergencies where the immediate loss of ventilation, refrigeration, water pumps, feeding systems or environmental controls could threaten livestock, crops or stored products.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBattle Short Mode should only be used by qualified personnel and in accordance with Cummins operating instructions.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFlexible Generator Exercise Scheduling\u003c\/h2\u003e\n\n\u003cp\u003eRoutine exercise helps confirm that the generator engine, starting system, alternator and controls are prepared for an outage. PowerCommand flexible exercise scheduling allows the operating time, frequency and duration to be adjusted around the needs of the agricultural facility.\u003c\/p\u003e\n\n\u003cp\u003eA properly planned exercise schedule can reduce unnecessary fuel use, emissions and noise while keeping the generator ready for emergency operation.\u003c\/p\u003e\n\n\u003ch2\u003eBrushless Alternator Performance\u003c\/h2\u003e\n\n\u003cp\u003eThe C150D6D uses a brushless, four-pole alternator designed to provide stable electrical output and strong motor-starting capability. Its low-reactance 2\/3-pitch windings help reduce waveform distortion when supporting nonlinear loads and electronic agricultural controls.\u003c\/p\u003e\n\n\u003ch3\u003eAlternator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eBrushless four-pole alternator design\u003c\/li\u003e\n  \u003cli\u003eDrip-proof revolving field\u003c\/li\u003e\n  \u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n  \u003cli\u003eDirect-coupled rotor\u003c\/li\u003e\n  \u003cli\u003eAutomatic voltage regulation\u003c\/li\u003e\n  \u003cli\u003eLow waveform distortion\u003c\/li\u003e\n  \u003cli\u003eShort-circuit fault-clearing capability\u003c\/li\u003e\n  \u003cli\u003eSelectable motor-starting capability\u003c\/li\u003e\n  \u003cli\u003eDirect-drive centrifugal cooling blower\u003c\/li\u003e\n  \u003cli\u003eFull single-phase output at the generator's rated capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHigh-Ambient Cooling System\u003c\/h2\u003e\n\n\u003cp\u003eThe standard set-mounted radiator cooling system is designed for operation in ambient temperatures up to 50°C or 122°F under applicable Cummins operating and derating conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe cooling package requires correctly designed airflow, ventilation and radiator-discharge provisions. Agricultural dust, debris and restricted airflow can affect generator performance and must be considered during installation.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Agricultural Applications\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDairy farms and automated milking systems\u003c\/li\u003e\n  \u003cli\u003ePoultry houses and ventilation equipment\u003c\/li\u003e\n  \u003cli\u003eLivestock barns and environmental controls\u003c\/li\u003e\n  \u003cli\u003eFeeding and watering systems\u003c\/li\u003e\n  \u003cli\u003eIrrigation pumps and agricultural well systems\u003c\/li\u003e\n  \u003cli\u003eGreenhouses and climate-control equipment\u003c\/li\u003e\n  \u003cli\u003eGrain elevators and handling systems\u003c\/li\u003e\n  \u003cli\u003eGrain drying and storage facilities\u003c\/li\u003e\n  \u003cli\u003eProduce refrigeration and cold storage\u003c\/li\u003e\n  \u003cli\u003eFarm shops and maintenance buildings\u003c\/li\u003e\n  \u003cli\u003eAgricultural processing equipment\u003c\/li\u003e\n  \u003cli\u003eLarge rural properties with single-phase service\u003c\/li\u003e\n  \u003cli\u003eEmergency power for critical farm infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMotor Starting and Load Sizing\u003c\/h2\u003e\n\n\u003cp\u003eAgricultural facilities frequently use irrigation pumps, ventilation fans, refrigeration compressors, augers, conveyors and other motors that draw substantially more current during startup than during normal operation.\u003c\/p\u003e\n\n\u003cp\u003eGenerator sizing should not be based only on total running wattage. A proper analysis must consider motor horsepower, locked-rotor current, starting method, voltage drop, load sequencing, simultaneous operation, elevation, ambient temperature and future equipment expansion.\u003c\/p\u003e\n\n\u003cp\u003eA qualified generator professional or electrical engineer should complete a load and motor-starting analysis before the generator is ordered.\u003c\/p\u003e\n\n\u003ch2\u003eOpen-Skid Agricultural Configuration\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eCummins A061T474 does not include a weather-protective or sound-attenuated enclosure.\u003c\/strong\u003e The engine, radiator, alternator, controls and generator components remain exposed on the structural skid.\u003c\/p\u003e\n\n\u003cp\u003eThe generator must be installed inside a properly designed generator room, agricultural equipment building or compatible separately purchased enclosure. The installation must provide adequate ventilation, combustion air, radiator discharge, weather protection, exhaust routing, service access and protection from unauthorized personnel.\u003c\/p\u003e\n\n\u003cp\u003eDo not order this model expecting an enclosed outdoor generator. Manufacturer or distributor images may show optional equipment or representative enclosed configurations that are not included with A061T474.\u003c\/p\u003e\n\n\u003ch2\u003eNo Diesel Fuel Tank Included\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eThis generator does not include an onboard, belly-mounted or sub-base diesel fuel tank.\u003c\/strong\u003e A properly sized external diesel fuel tank or compatible separately purchased sub-base tank must be provided.\u003c\/p\u003e\n\n\u003cp\u003eThe fuel system should be designed for the desired emergency runtime and account for supply and return piping, fuel lift, filtration, containment, fuel quality, environmental requirements and applicable fire codes.\u003c\/p\u003e\n\n\u003ch2\u003eAutomatic Transfer Switch Not Included\u003c\/h2\u003e\n\n\u003cp\u003eAn automatic transfer switch is not included. A properly selected transfer switch is required for automatic standby operation of a building or electrical service.\u003c\/p\u003e\n\n\u003cp\u003eThe transfer switch must match the facility's 120\/240V single-phase service, required amperage, service-entrance arrangement and applicable electrical codes. Depending on the application, an 800-amp transfer switch or a separately engineered load-distribution system may be required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNever connect the generator directly to utility-supplied wiring without approved transfer equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eStarting Batteries Required\u003c\/h2\u003e\n\n\u003cp\u003eThe agricultural configuration requires \u003cstrong\u003etwo properly sized 12-volt starting batteries\u003c\/strong\u003e. Batteries, battery cables and an external battery charger are not included unless specifically listed on the final sales order.\u003c\/p\u003e\n\n\u003cp\u003eConfirm the required cold-cranking-amp rating, battery group size, cable length, charger and cold-weather accessories during installation planning.\u003c\/p\u003e\n\n\u003ch2\u003eCummins C150D6D A061T474 Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins Power Generation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eC150D6D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA061T474\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAgricultural-spec open diesel generator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEmergency agricultural standby power\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandby Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150kW \/ 188kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120\/240V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFull-Load Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 625 amps at 120\/240V single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMain Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e800 amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDiesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSB7-G5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCast-iron inline six-cylinder, four-cycle diesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Displacement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 6.7 liters\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAspiration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTurbocharged and charge-air cooled\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Engine Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,800 RPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompression Ratio\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17.2:1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLubricating-Oil Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17.4 liters \/ approximately 18.4 quarts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLiquid cooled with set-mounted radiator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling-System Ambient Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 50°C \/ 122°F under applicable Cummins conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling-System Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 22 liters \/ 5.9 gallons with radiator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins PowerCommand 1.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eElectric start with automatic remote-start capability\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Batteries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwo 12V batteries required; not included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternator Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrushless, four-pole, drip-proof revolving field\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternator Windings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow-reactance 2\/3-pitch windings\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMotor-Starting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 770 kVA shunt or 920 kVA with PMG at 90% sustained voltage, depending on alternator configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Consumption at 25% Standby Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 4.7 gallons per hour\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Consumption at 50% Standby Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 6.9 gallons per hour\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Consumption at 75% Standby Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 9.2 gallons per hour\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Consumption at 100% Standby Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 11.7 gallons per hour\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Open-Set Wet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3,064 pounds before configuration-specific options\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEmissions Classification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEPA Tier 3 stationary emergency\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBattle Short Mode\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFlexible Exercise Scheduling\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeather Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSound Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiesel Fuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAutomatic Transfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOpen structural skid\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProfessional installation required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins C150D6D agricultural diesel generator set\u003c\/li\u003e\n  \u003cli\u003eCummins QSB7-G5 industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase alternator\u003c\/li\u003e\n  \u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n  \u003cli\u003e800-amp main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eSet-mounted radiator and liquid-cooling system\u003c\/li\u003e\n  \u003cli\u003eOpen structural generator skid\u003c\/li\u003e\n  \u003cli\u003eStandard factory equipment associated with A061T474\u003c\/li\u003e\n  \u003cli\u003eCummins manufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat Is Not Included\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eWeather-protective enclosure\u003c\/li\u003e\n  \u003cli\u003eSound-attenuated enclosure\u003c\/li\u003e\n  \u003cli\u003eIntegrated, belly-mounted or sub-base diesel fuel tank\u003c\/li\u003e\n  \u003cli\u003eAutomatic transfer switch\u003c\/li\u003e\n  \u003cli\u003eRequired starting batteries\u003c\/li\u003e\n  \u003cli\u003eBattery cables or external battery charger unless listed\u003c\/li\u003e\n  \u003cli\u003eConcrete generator pad or engineered foundation\u003c\/li\u003e\n  \u003cli\u003eExternal exhaust piping and installation\u003c\/li\u003e\n  \u003cli\u003eFuel lines, fuel filtration or fuel-system installation\u003c\/li\u003e\n  \u003cli\u003eElectrical wiring and installation materials\u003c\/li\u003e\n  \u003cli\u003ePermits, engineering or site preparation\u003c\/li\u003e\n  \u003cli\u003eGenerator building or separately purchased enclosure\u003c\/li\u003e\n  \u003cli\u003eForklift, crane or unloading services\u003c\/li\u003e\n  \u003cli\u003eStartup or commissioning unless purchased separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eProfessional Installation Required\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C150D6D must be installed by qualified generator, electrical, mechanical, exhaust and fuel-system professionals. The completed installation must comply with Cummins requirements and all applicable national, state and local electrical, fuel, fire, emissions, environmental and building codes.\u003c\/p\u003e\n\n\u003cp\u003eInstallation planning should address:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eComplete electrical-load analysis\u003c\/li\u003e\n  \u003cli\u003eMotor-starting and locked-rotor current\u003c\/li\u003e\n  \u003cli\u003eLoad sequencing and load management\u003c\/li\u003e\n  \u003cli\u003eAutomatic transfer-switch sizing\u003c\/li\u003e\n  \u003cli\u003eFoundation and vibration isolation\u003c\/li\u003e\n  \u003cli\u003eWeather protection for the open generator\u003c\/li\u003e\n  \u003cli\u003eCombustion air and radiator airflow\u003c\/li\u003e\n  \u003cli\u003eExhaust routing and backpressure\u003c\/li\u003e\n  \u003cli\u003eDiesel fuel storage and containment\u003c\/li\u003e\n  \u003cli\u003eGrounding and electrical protection\u003c\/li\u003e\n  \u003cli\u003eStarting batteries and battery charging\u003c\/li\u003e\n  \u003cli\u003eMaintenance and service clearances\u003c\/li\u003e\n  \u003cli\u003eEmergency shutdown requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFreight Shipping and Delivery\u003c\/h2\u003e\n\n\u003cp\u003eThis commercial agricultural generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the generator.\u003c\/p\u003e\n\n\u003cp\u003eA properly rated forklift, crane or other lifting equipment will normally be required. Standard liftgate service may not be available or sufficient for unloading this industrial generator.\u003c\/p\u003e\n\n\u003cp\u003eFarm delivery, residential delivery, limited-access service, jobsite delivery, storage, redelivery, reconsignment and other special freight services may result in additional charges.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInspect the generator and shipping materials before signing the delivery receipt.\u003c\/strong\u003e Any visible damage, missing components or packaging concerns must be clearly documented on the carrier's delivery receipt at the time of delivery.\u003c\/p\u003e\n\n\u003ch2\u003eCummins Limited Warranty\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C150D6D A061T474 is covered by the applicable \u003cstrong\u003eCummins two-year limited generator-set warranty\u003c\/strong\u003e. Warranty coverage is subject to Cummins terms, application limitations, operating-hour limits, maintenance requirements and exclusions.\u003c\/p\u003e\n\n\u003cp\u003eThe generator should be registered after installation. Authorized startup, documented maintenance and the use of approved parts and fluids may be required to preserve warranty coverage.\u003c\/p\u003e\n\n\u003cp\u003eRefer to the Cummins limited warranty statement supplied with the generator for the complete and controlling warranty terms.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eIs A061T474 the agricultural version of the Cummins C150D6D?\u003c\/h3\u003e\n\u003cp\u003eYes. A061T474 is the agricultural-spec C150D6D configured for 150kW standby output at 120\/240V single phase.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this generator include an enclosure?\u003c\/h3\u003e\n\u003cp\u003eNo. This is an open-skid generator without a weather-protective or sound-attenuated enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eCan the generator be installed outdoors as delivered?\u003c\/h3\u003e\n\u003cp\u003eNo. The exposed generator requires a properly engineered equipment building or compatible separately purchased weather enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eDoes A061T474 include a diesel fuel tank?\u003c\/h3\u003e\n\u003cp\u003eNo. It does not include an onboard, belly-mounted or sub-base fuel tank. A properly sized external fuel system is required.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the generator include an automatic transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. Transfer equipment must be purchased separately and selected for the facility's service voltage, phase, amperage and applicable code requirements.\u003c\/p\u003e\n\n\u003ch3\u003eHow much standby power does the C150D6D produce?\u003c\/h3\u003e\n\u003cp\u003eThe generator is rated for 150kW of emergency standby power.\u003c\/p\u003e\n\n\u003ch3\u003eWhat voltage and phase does it produce?\u003c\/h3\u003e\n\u003cp\u003eA061T474 produces 120\/240V single-phase, 60 Hz electrical power.\u003c\/p\u003e\n\n\u003ch3\u003eHow many amps does it produce?\u003c\/h3\u003e\n\u003cp\u003eThe Cummins single-phase alternator data lists approximately 625 full-load amps at the 150kW standby rating. The agricultural package includes an 800-amp circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eWhat engine is installed in the generator?\u003c\/h3\u003e\n\u003cp\u003eThe C150D6D uses a Cummins QSB7-G5 6.7-liter, inline six-cylinder industrial diesel engine operating at 1,800 RPM.\u003c\/p\u003e\n\n\u003ch3\u003eHow much diesel fuel does it consume?\u003c\/h3\u003e\n\u003cp\u003eManufacturer data lists approximately 6.9 gallons per hour at 50% standby load and 11.7 gallons per hour at full standby load. Actual consumption varies with load, installation and operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003eAre starting batteries included?\u003c\/h3\u003e\n\u003cp\u003eNo. Two properly sized 12V starting batteries are required and are not included unless specifically stated on the final sales order.\u003c\/p\u003e\n\n\u003ch3\u003eCan this generator power an entire farm?\u003c\/h3\u003e\n\u003cp\u003eIt may support a substantial portion of a farm's electrical load, but a professional load and motor-starting analysis is required before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCan it start large irrigation pumps?\u003c\/h3\u003e\n\u003cp\u003ePotentially. Suitability depends on pump horsepower, motor voltage, locked-rotor current, starting method, wiring distance and other loads operating at the same time.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is PowerCommand 1.1?\u003c\/h3\u003e\n\u003cp\u003ePowerCommand 1.1 is Cummins' integrated electronic generator-control system. It manages remote starting, voltage and frequency regulation, output metering, fault protection and system diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is Battle Short Mode?\u003c\/h3\u003e\n\u003cp\u003eBattle Short Mode allows selected protective shutdowns to be overridden when maintaining power is considered more critical than protecting the generator from possible damage.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the generator exercise automatically?\u003c\/h3\u003e\n\u003cp\u003eYes. PowerCommand controls provide flexible exercise scheduling that can be programmed for the preferred time, duration and frequency.\u003c\/p\u003e\n\n\u003ch3\u003eIs the automatic transfer switch required?\u003c\/h3\u003e\n\u003cp\u003eApproved transfer equipment is required when connecting the generator to a building or utility-supplied electrical system.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this generator require professional installation?\u003c\/h3\u003e\n\u003cp\u003eYes. Professional generator, electrical, mechanical, exhaust and fuel-system installation is required.\u003c\/p\u003e\n\n\u003ch2\u003eImportant Ordering Information\u003c\/h2\u003e\n\n\u003cp\u003eCommercial generators may be factory built, configured or allocated for a specific customer order. Confirm the following before purchasing:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins part number A061T474\u003c\/li\u003e\n  \u003cli\u003eC150D6D agricultural configuration\u003c\/li\u003e\n  \u003cli\u003e150kW standby rating\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase output\u003c\/li\u003e\n  \u003cli\u003e800-amp circuit breaker\u003c\/li\u003e\n  \u003cli\u003eOpen generator configuration\u003c\/li\u003e\n  \u003cli\u003eNo enclosure included\u003c\/li\u003e\n  \u003cli\u003eNo diesel fuel tank included\u003c\/li\u003e\n  \u003cli\u003eNo automatic transfer switch included\u003c\/li\u003e\n  \u003cli\u003eNo starting batteries included\u003c\/li\u003e\n  \u003cli\u003eLocal emissions eligibility\u003c\/li\u003e\n  \u003cli\u003eCurrent production lead time\u003c\/li\u003e\n  \u003cli\u003eFinal factory-installed options\u003c\/li\u003e\n  \u003cli\u003eFreight and unloading requirements\u003c\/li\u003e\n  \u003cli\u003eCancellation and return restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Cummins Power Generation\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e C150D6D\u003cbr\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e A061T474\u003cbr\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Agricultural standby power\u003cbr\u003e\n\u003cstrong\u003eStandby Rating:\u003c\/strong\u003e 150kW\u003cbr\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240V\u003cbr\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003cbr\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003cbr\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Diesel\u003cbr\u003e\n\u003cstrong\u003eMain Circuit Breaker:\u003c\/strong\u003e 800 amps\u003cbr\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Open-skid generator with no enclosure or fuel tank\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications, availability and standard factory equipment are subject to change. Product images may show optional equipment or a representative configuration. The final Cummins order acknowledgment and order-specific submittal documents determine the exact equipment supplied.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":45297353392243,"sku":"A061T474","price":39288.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/2359\/7385\/files\/cummins-c150d6d-150kw-agriculture-generator-a061t474.jpg?v=1785515355","url":"https:\/\/allprogenerators.com\/products\/cummins-c150d6d-150kw-agriculture-generator-a061t474","provider":"AllProGenerators","version":"1.0","type":"link"}