{"product_id":"cummins-c175d6d-175kw-agriculture-generator-a061t476","title":"Cummins C175D6D 175kW Agriculture Diesel Generator 120\/240V 1-Phase | A061T476","description":"\u003ch2\u003eCummins C175D6D 175kW Agricultural Diesel Generator\u003c\/h2\u003e\n\u003cp\u003eProtect essential farm operations during utility outages with the \u003cstrong\u003eCummins C175D6D 175kW Agricultural Diesel Generator\u003c\/strong\u003e. Cummins part number \u003cstrong\u003eA061T476\u003c\/strong\u003e is a factory-configured agricultural standby generator designed for farms, dairy facilities, poultry houses, livestock operations, irrigation systems, grain facilities, greenhouses, agricultural refrigeration and other applications requiring dependable 120\/240-volt single-phase backup power.\u003c\/p\u003e\n\u003cp\u003eThis heavy-duty farm generator delivers \u003cstrong\u003e175kW of emergency standby power\u003c\/strong\u003e at \u003cstrong\u003e120\/240V single phase\u003c\/strong\u003e. It combines a Cummins QSB7-G5 industrial diesel engine, brushless four-pole alternator, PowerCommand 1.1 electronic controls and an \u003cstrong\u003e800-amp main circuit breaker\u003c\/strong\u003e in an open-skid agricultural configuration.\u003c\/p\u003e\n\u003cdiv style=\"padding: 16px; margin: 20px 0; border: 2px solid #b42318; background-color: #fff5f5;\"\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eImportant Agricultural Configuration Notice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eCummins A061T476 is an open generator set. It does not include a weather enclosure, sound-attenuated enclosure or diesel fuel tank.\u003c\/strong\u003e It requires a properly designed generator building or separately purchased enclosure, an external diesel fuel system, two starting batteries, transfer equipment and professional installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e175kW Standby Power for Agricultural Operations\u003c\/h2\u003e\n\u003cp\u003eModern agricultural facilities rely on electricity for ventilation, refrigeration, irrigation, milking systems, feeding equipment, grain handling, water pumps, lighting and environmental controls. A utility outage can quickly place livestock, crops, stored products and daily production at risk.\u003c\/p\u003e\n\u003cp\u003eThe Cummins C175D6D is designed to provide dependable emergency power and fast response as electrical loads change. Its high-capacity 120\/240V single-phase output is suitable for larger farms and rural facilities with substantial single-phase electrical services.\u003c\/p\u003e\n\u003cp\u003eWhen paired with a properly selected automatic transfer switch, the generator can automatically start after a utility-power failure and supply approved farm loads until utility service returns.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e175kW emergency standby power rating\u003c\/li\u003e\n\u003cli\u003e120\/240V single-phase electrical output\u003c\/li\u003e\n\u003cli\u003e60 Hz operating frequency\u003c\/li\u003e\n\u003cli\u003eApproximately 729 amps at full 175kW output\u003c\/li\u003e\n\u003cli\u003e800-amp adjustable main circuit breaker\u003c\/li\u003e\n\u003cli\u003eCummins QSB7-G5 industrial diesel engine\u003c\/li\u003e\n\u003cli\u003e6.69-liter heavy-duty engine\u003c\/li\u003e\n\u003cli\u003eTurbocharged and charge-air-cooled operation\u003c\/li\u003e\n\u003cli\u003e1,800 RPM rated engine speed\u003c\/li\u003e\n\u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n\u003cli\u003eAutomatic remote-start and stop capability\u003c\/li\u003e\n\u003cli\u003eBattle Short Mode\u003c\/li\u003e\n\u003cli\u003eFlexible generator exercise scheduling\u003c\/li\u003e\n\u003cli\u003eIntegrated generator protection and diagnostics\u003c\/li\u003e\n\u003cli\u003eBrushless four-pole alternator\u003c\/li\u003e\n\u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n\u003cli\u003eLow waveform distortion\u003c\/li\u003e\n\u003cli\u003eHigh-ambient liquid-cooling system\u003c\/li\u003e\n\u003cli\u003eOpen-skid agricultural configuration\u003c\/li\u003e\n\u003cli\u003eNo enclosure or diesel fuel tank included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCummins QSB7-G5 Industrial Diesel Engine\u003c\/h2\u003e\n\u003cp\u003eThe C175D6D agricultural generator is powered by the \u003cstrong\u003eCummins QSB7-G5\u003c\/strong\u003e, a rugged 6.69-liter, four-cycle industrial diesel engine engineered for stationary power-generation applications.\u003c\/p\u003e\n\u003cp\u003eThe engine uses turbocharging and charge-air cooling to provide dependable power and rapid response when agricultural loads start or change. Its 1,800 RPM operating speed is designed for stationary standby-generator service.\u003c\/p\u003e\n\u003cp\u003eHeavy-duty cast-iron construction, liquid cooling, a spin-on oil filter and an engine-driven battery-charging alternator support dependable emergency operation when the generator is correctly installed and maintained.\u003c\/p\u003e\n\u003ch3\u003eEngine Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCummins QSB7-G5 diesel engine\u003c\/li\u003e\n\u003cli\u003e6.69-liter displacement\u003c\/li\u003e\n\u003cli\u003eHeavy-duty cast-iron construction\u003c\/li\u003e\n\u003cli\u003eFour-cycle industrial design\u003c\/li\u003e\n\u003cli\u003eTurbocharged and charge-air cooled\u003c\/li\u003e\n\u003cli\u003eLiquid-cooled operation\u003c\/li\u003e\n\u003cli\u003e1,800 RPM rated speed\u003c\/li\u003e\n\u003cli\u003eEngine-driven battery-charging alternator\u003c\/li\u003e\n\u003cli\u003eSpin-on oil filter with pressure-relief valve\u003c\/li\u003e\n\u003cli\u003eDesigned for rapid response to load changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePowerCommand 1.1 Electronic Control System\u003c\/h2\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003eCummins PowerCommand 1.1\u003c\/strong\u003e control system coordinates the generator engine, alternator and protective functions. It supports automatic operation when connected to compatible transfer equipment and provides generator monitoring, voltage regulation, frequency regulation, fault protection and system diagnostics.\u003c\/p\u003e\n\u003ch3\u003ePowerCommand Control Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic remote starting and stopping\u003c\/li\u003e\n\u003cli\u003ePrecise voltage regulation\u003c\/li\u003e\n\u003cli\u003ePrecise frequency regulation\u003c\/li\u003e\n\u003cli\u003eGenerator output metering\u003c\/li\u003e\n\u003cli\u003eEngine and generator status monitoring\u003c\/li\u003e\n\u003cli\u003eAlarm and operating-status display\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown when qualifying faults are detected\u003c\/li\u003e\n\u003cli\u003eIntegrated generator protection\u003c\/li\u003e\n\u003cli\u003eIndustry-leading self-diagnostic capabilities\u003c\/li\u003e\n\u003cli\u003eNFPA 110 Level 1 control functionality\u003c\/li\u003e\n\u003cli\u003eProgrammable exercise scheduling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBattle Short Mode\u003c\/h2\u003e\n\u003cp\u003eBattle Short Mode allows selected generator-protection shutdowns to be overridden when maintaining electrical power is considered more important than protecting the generator from possible damage.\u003c\/p\u003e\n\u003cp\u003eThis capability may be valuable during an agricultural emergency where the immediate loss of ventilation, refrigeration, water pumps, feeding systems or environmental controls could threaten livestock, crops or stored products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattle Short Mode must only be used by qualified personnel and in accordance with Cummins operating instructions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eFlexible Generator Exercise Scheduling\u003c\/h2\u003e\n\u003cp\u003eRoutine generator exercise helps verify that the engine, starting system, alternator and controls are prepared for a utility outage. PowerCommand flexible exercise scheduling allows the operating time, frequency and duration to be programmed around the needs of the agricultural facility.\u003c\/p\u003e\n\u003cp\u003eA properly planned exercise schedule can help reduce unnecessary diesel consumption, noise and emissions while keeping the generator ready for emergency operation.\u003c\/p\u003e\n\u003ch2\u003eBrushless Alternator Performance\u003c\/h2\u003e\n\u003cp\u003eThe Cummins alternator uses a brushless, four-pole revolving-field design with low-reactance 2\/3-pitch windings. This configuration helps provide stable voltage, low waveform distortion and dependable motor-starting performance for demanding agricultural loads.\u003c\/p\u003e\n\u003ch3\u003eAlternator Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrushless four-pole design\u003c\/li\u003e\n\u003cli\u003eDrip-proof revolving field\u003c\/li\u003e\n\u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n\u003cli\u003eDirect-coupled rotor\u003c\/li\u003e\n\u003cli\u003eAutomatic voltage regulation\u003c\/li\u003e\n\u003cli\u003eLess than 5% total harmonic distortion\u003c\/li\u003e\n\u003cli\u003eShort-circuit fault-clearing capability\u003c\/li\u003e\n\u003cli\u003eSelectable motor-starting capability\u003c\/li\u003e\n\u003cli\u003eDirect-drive centrifugal cooling blower\u003c\/li\u003e\n\u003cli\u003eFull single-phase output at the generator's standby rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHigh-Ambient Cooling System\u003c\/h2\u003e\n\u003cp\u003eThe standard generator cooling package is designed to support operation in ambient temperatures up to 50°C or 122°F under applicable Cummins operating and derating conditions.\u003c\/p\u003e\n\u003cp\u003eProper installation must provide adequate combustion air, radiator airflow and discharge ventilation. Agricultural dust, debris and restricted airflow can reduce cooling performance and should be addressed during site design.\u003c\/p\u003e\n\u003cp\u003eCoolant heaters are included with the agricultural configuration to help support reliable cold-weather starting when correctly powered and installed.\u003c\/p\u003e\n\u003ch2\u003eCommon Agricultural Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDairy farms and automated milking systems\u003c\/li\u003e\n\u003cli\u003ePoultry houses and ventilation equipment\u003c\/li\u003e\n\u003cli\u003eLivestock barns and environmental controls\u003c\/li\u003e\n\u003cli\u003eAutomated feeding and watering equipment\u003c\/li\u003e\n\u003cli\u003eIrrigation pumps and agricultural wells\u003c\/li\u003e\n\u003cli\u003eGreenhouses and climate-control systems\u003c\/li\u003e\n\u003cli\u003eGrain elevators and material-handling systems\u003c\/li\u003e\n\u003cli\u003eGrain drying and storage facilities\u003c\/li\u003e\n\u003cli\u003eProduce refrigeration and cold storage\u003c\/li\u003e\n\u003cli\u003eFarm shops and equipment buildings\u003c\/li\u003e\n\u003cli\u003eAgricultural processing equipment\u003c\/li\u003e\n\u003cli\u003eLarge rural properties with single-phase service\u003c\/li\u003e\n\u003cli\u003eEmergency power for critical farm infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMotor Starting and Generator Sizing\u003c\/h2\u003e\n\u003cp\u003eAgricultural facilities commonly operate irrigation pumps, ventilation fans, refrigeration compressors, augers, conveyors and other electric motors that can draw substantially more current during startup than during normal operation.\u003c\/p\u003e\n\u003cp\u003eGenerator selection should not be based only on total running wattage. A proper analysis should consider motor horsepower, locked-rotor current, starting method, voltage drop, load sequencing, simultaneous operation, elevation, ambient temperature and possible future expansion.\u003c\/p\u003e\n\u003cp\u003eA qualified generator professional or electrical engineer should complete a detailed load and motor-starting analysis before the generator is ordered.\u003c\/p\u003e\n\u003ch2\u003eOpen-Skid Agricultural Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCummins A061T476 does not include a weather-protective or sound-attenuated enclosure.\u003c\/strong\u003e The engine, radiator, alternator, controls and other generator components remain exposed on the open structural skid.\u003c\/p\u003e\n\u003cp\u003eThe generator must be installed inside a properly designed generator room, agricultural equipment building or compatible separately purchased enclosure. The installation must provide adequate ventilation, combustion air, radiator discharge, weather protection, exhaust routing, service access and protection from unauthorized personnel.\u003c\/p\u003e\n\u003cp\u003eDo not order this model expecting an enclosed outdoor generator. Cummins and distributor images may show optional equipment or representative configurations that are not included with A061T476.\u003c\/p\u003e\n\u003ch2\u003eNo Diesel Fuel Tank Included\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis generator does not include an onboard, belly-mounted or sub-base diesel fuel tank.\u003c\/strong\u003e A properly sized external diesel fuel tank or compatible separately purchased sub-base tank must be provided as part of the installation.\u003c\/p\u003e\n\u003cp\u003eThe fuel system should account for the desired emergency runtime, fuel consumption, supply and return piping, maximum fuel lift, filtration, containment, fuel quality and applicable fire and environmental regulations.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Transfer Switch Not Included\u003c\/h2\u003e\n\u003cp\u003eAn automatic transfer switch is not included. Approved transfer equipment is required for automatic backup of a building or electrical service.\u003c\/p\u003e\n\u003cp\u003eThe transfer switch must match the farm's 120\/240V single-phase service, required amperage, service-entrance arrangement and applicable electrical codes. An 800-amp transfer switch or a separately engineered load-distribution and load-management system may be required, depending on the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNever connect the generator directly to utility-supplied wiring without approved transfer equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eStarting Batteries Required\u003c\/h2\u003e\n\u003cp\u003eThe Cummins C175D6D agricultural generator requires \u003cstrong\u003etwo 12-volt starting batteries rated at approximately 850 cold-cranking amps each\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eStarting batteries are not included. Battery cables and an external battery charger are also not included unless specifically listed on the final sales order.\u003c\/p\u003e\n\u003ch2\u003eCummins C175D6D A061T476 Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCummins Power Generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC175D6D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA061T476\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgricultural Spec Diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency agricultural standby power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Full-Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 729 amps at 175kW and 240V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 amps, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCummins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSB7-G5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Displacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.69 liters \/ 6,690 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty four-cycle industrial diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAspiration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbocharged and charge-air cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Engine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid cooled with set-mounted radiator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling-System Ambient Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 50°C \/ 122°F under applicable Cummins conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Battery-Charging Alternator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCummins PowerCommand 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual electric start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting Battery Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12V, approximately 850 CCA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting Batteries Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternator Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrushless four-pole revolving field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternator Windings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-reactance 2\/3-pitch windings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 5% from no load to full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Consumption at 50% Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 6.8 gallons per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Consumption at 100% Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 12.7 gallons per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Product Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,179 pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200 listed agricultural configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattle Short Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible Exercise Scheduling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeather Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiesel Fuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Transfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen structural skid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalifornia Availability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for sale or use in California\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProfessional installation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCummins C175D6D agricultural diesel generator set\u003c\/li\u003e\n\u003cli\u003eCummins QSB7-G5 industrial diesel engine\u003c\/li\u003e\n\u003cli\u003e120\/240V single-phase alternator\u003c\/li\u003e\n\u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n\u003cli\u003e800-amp adjustable main circuit breaker\u003c\/li\u003e\n\u003cli\u003eSet-mounted radiator and liquid-cooling system\u003c\/li\u003e\n\u003cli\u003eCoolant heaters\u003c\/li\u003e\n\u003cli\u003eOpen structural generator skid\u003c\/li\u003e\n\u003cli\u003eStandard factory equipment associated with A061T476\u003c\/li\u003e\n\u003cli\u003eCummins manufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat Is Not Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWeather-protective enclosure\u003c\/li\u003e\n\u003cli\u003eSound-attenuated enclosure\u003c\/li\u003e\n\u003cli\u003eIntegrated, belly-mounted or sub-base diesel fuel tank\u003c\/li\u003e\n\u003cli\u003eAutomatic transfer switch\u003c\/li\u003e\n\u003cli\u003eTwo required 12V starting batteries\u003c\/li\u003e\n\u003cli\u003eBattery cables or external battery charger unless listed\u003c\/li\u003e\n\u003cli\u003eConcrete generator pad or engineered foundation\u003c\/li\u003e\n\u003cli\u003eExternal exhaust piping and installation\u003c\/li\u003e\n\u003cli\u003eFuel lines, fuel filtration or fuel-system installation\u003c\/li\u003e\n\u003cli\u003eElectrical wiring and installation materials\u003c\/li\u003e\n\u003cli\u003ePermits, engineering or site preparation\u003c\/li\u003e\n\u003cli\u003eGenerator building or separately purchased enclosure\u003c\/li\u003e\n\u003cli\u003eForklift, crane or unloading services\u003c\/li\u003e\n\u003cli\u003eStartup or commissioning unless purchased separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProfessional Installation Required\u003c\/h2\u003e\n\u003cp\u003eThe Cummins C175D6D must be installed by qualified generator, electrical, mechanical, exhaust and fuel-system professionals. The completed installation must comply with Cummins requirements and all applicable national, state and local electrical, fire, fuel, emissions, environmental and building codes.\u003c\/p\u003e\n\u003cp\u003eInstallation planning should address:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete electrical-load analysis\u003c\/li\u003e\n\u003cli\u003eMotor-starting and locked-rotor current\u003c\/li\u003e\n\u003cli\u003eLoad sequencing and load management\u003c\/li\u003e\n\u003cli\u003eAutomatic transfer-switch sizing\u003c\/li\u003e\n\u003cli\u003eFoundation and vibration isolation\u003c\/li\u003e\n\u003cli\u003eWeather protection for the open generator\u003c\/li\u003e\n\u003cli\u003eCombustion air and radiator airflow\u003c\/li\u003e\n\u003cli\u003eExhaust routing and permissible backpressure\u003c\/li\u003e\n\u003cli\u003eDiesel fuel storage and containment\u003c\/li\u003e\n\u003cli\u003eGrounding and electrical protection\u003c\/li\u003e\n\u003cli\u003eStarting batteries and battery charging\u003c\/li\u003e\n\u003cli\u003eMaintenance and service clearances\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFreight Shipping and Delivery\u003c\/h2\u003e\n\u003cp\u003eThis commercial agricultural generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the generator.\u003c\/p\u003e\n\u003cp\u003eA properly rated forklift, crane or other lifting equipment will normally be required. Standard liftgate service may not be available or sufficient for unloading a generator weighing approximately 3,179 pounds.\u003c\/p\u003e\n\u003cp\u003eFarm delivery, residential delivery, limited-access service, jobsite delivery, storage, redelivery, reconsignment and other special freight services may result in additional charges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the generator and shipping materials before signing the delivery receipt.\u003c\/strong\u003e Any visible damage, missing components or packaging concerns must be clearly documented on the carrier's delivery receipt at the time of delivery.\u003c\/p\u003e\n\u003ch2\u003eCummins Limited Warranty\u003c\/h2\u003e\n\u003cp\u003eThe Cummins C175D6D A061T476 is covered by the applicable \u003cstrong\u003eCummins two-year limited generator-set warranty\u003c\/strong\u003e. Warranty coverage is subject to Cummins terms, application limitations, operating-hour limits, maintenance requirements and exclusions.\u003c\/p\u003e\n\u003cp\u003eThe generator should be registered after installation. Authorized startup, documented maintenance and the use of approved parts and fluids may be required to preserve warranty coverage.\u003c\/p\u003e\n\u003cp\u003eRefer to the Cummins limited warranty statement supplied with the generator for the complete and controlling warranty terms.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs A061T476 the agricultural version of the Cummins C175D6D?\u003c\/h3\u003e\n\u003cp\u003eYes. A061T476 is the agricultural-spec C175D6D configured for 175kW of emergency standby power at 120\/240V single phase.\u003c\/p\u003e\n\u003ch3\u003eDoes this generator include an enclosure?\u003c\/h3\u003e\n\u003cp\u003eNo. It is an open-skid generator without a weather-protective or sound-attenuated enclosure.\u003c\/p\u003e\n\u003ch3\u003eCan this generator be installed outdoors as delivered?\u003c\/h3\u003e\n\u003cp\u003eNo. The exposed generator requires a properly engineered equipment building or compatible separately purchased weather enclosure.\u003c\/p\u003e\n\u003ch3\u003eDoes A061T476 include a diesel fuel tank?\u003c\/h3\u003e\n\u003cp\u003eNo. It does not include an onboard, belly-mounted or sub-base fuel tank. A properly sized external diesel fuel system is required.\u003c\/p\u003e\n\u003ch3\u003eDoes it include an automatic transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. Transfer equipment must be purchased separately and selected for the farm's service voltage, phase, amperage and applicable code requirements.\u003c\/p\u003e\n\u003ch3\u003eHow much standby power does the C175D6D produce?\u003c\/h3\u003e\n\u003cp\u003eThe A061T476 agricultural configuration is rated for 175kW of emergency standby power.\u003c\/p\u003e\n\u003ch3\u003eWhat voltage and phase does it produce?\u003c\/h3\u003e\n\u003cp\u003eIt produces 120\/240V single-phase, 60 Hz electrical power.\u003c\/p\u003e\n\u003ch3\u003eHow many amps does the generator produce?\u003c\/h3\u003e\n\u003cp\u003eA 175kW load at 240V single phase calculates to approximately 729 amps. The agricultural package includes an 800-amp adjustable circuit breaker.\u003c\/p\u003e\n\u003ch3\u003eWhat engine is installed in the generator?\u003c\/h3\u003e\n\u003cp\u003eThe C175D6D uses a Cummins QSB7-G5 6.69-liter industrial diesel engine operating at 1,800 RPM.\u003c\/p\u003e\n\u003ch3\u003eHow much diesel fuel does it consume?\u003c\/h3\u003e\n\u003cp\u003ePublished product data lists approximately 6.8 gallons per hour at 50% load and 12.7 gallons per hour at full standby load. Actual consumption varies with load, fuel quality, installation and operating conditions.\u003c\/p\u003e\n\u003ch3\u003eAre starting batteries included?\u003c\/h3\u003e\n\u003cp\u003eNo. The generator requires two 12V starting batteries rated at approximately 850 cold-cranking amps each. Batteries are not included unless specifically stated on the final sales order.\u003c\/p\u003e\n\u003ch3\u003eCan this generator power an entire farm?\u003c\/h3\u003e\n\u003cp\u003eIt may support a substantial portion of a farm's electrical load, but a professional load and motor-starting analysis is required before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan it start large irrigation pumps?\u003c\/h3\u003e\n\u003cp\u003ePotentially. Suitability depends on pump horsepower, motor voltage, locked-rotor current, starting method, wiring distance and other equipment operating at the same time.\u003c\/p\u003e\n\u003ch3\u003eWhat is PowerCommand 1.1?\u003c\/h3\u003e\n\u003cp\u003ePowerCommand 1.1 is Cummins' integrated electronic generator-control system. It manages remote starting, voltage and frequency regulation, output metering, fault protection and system diagnostics.\u003c\/p\u003e\n\u003ch3\u003eWhat is Battle Short Mode?\u003c\/h3\u003e\n\u003cp\u003eBattle Short Mode allows selected protective shutdowns to be overridden when maintaining power is considered more critical than protecting the generator from possible damage.\u003c\/p\u003e\n\u003ch3\u003eDoes the generator exercise automatically?\u003c\/h3\u003e\n\u003cp\u003eYes. PowerCommand provides flexible exercise scheduling that can be programmed for the preferred time, duration and frequency.\u003c\/p\u003e\n\u003ch3\u003eIs this generator intended for prime power?\u003c\/h3\u003e\n\u003cp\u003eThis specific A061T476 agricultural package is marketed for emergency standby applications. Do not use or advertise it for prime power without written application approval from Cummins.\u003c\/p\u003e\n\u003ch3\u003eWhat are the generator dimensions?\u003c\/h3\u003e\n\u003cp\u003eThe open generator measures approximately 113 inches long, 40 inches wide and 56 inches high. Use the order-specific Cummins outline drawing for final foundation and installation planning.\u003c\/p\u003e\n\u003ch3\u003eHow much does the generator weigh?\u003c\/h3\u003e\n\u003cp\u003eThe published product weight is approximately 3,179 pounds. Confirm the final shipping weight before arranging unloading equipment.\u003c\/p\u003e\n\u003ch3\u003eDoes this generator require professional installation?\u003c\/h3\u003e\n\u003cp\u003eYes. Professional generator, electrical, mechanical, exhaust and fuel-system installation is required.\u003c\/p\u003e\n\u003ch3\u003eCan this generator be sold or used in California?\u003c\/h3\u003e\n\u003cp\u003eThis specific agricultural configuration is listed as not for sale or use in California.\u003c\/p\u003e\n\u003ch2\u003eImportant Ordering Information\u003c\/h2\u003e\n\u003cp\u003eCommercial generators may be factory built, configured or allocated for a specific customer order. Confirm the following before purchasing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCummins part number A061T476\u003c\/li\u003e\n\u003cli\u003eC175D6D agricultural configuration\u003c\/li\u003e\n\u003cli\u003e175kW standby rating\u003c\/li\u003e\n\u003cli\u003e120\/240V single-phase output\u003c\/li\u003e\n\u003cli\u003e800-amp adjustable circuit breaker\u003c\/li\u003e\n\u003cli\u003eOpen generator configuration\u003c\/li\u003e\n\u003cli\u003eNo enclosure included\u003c\/li\u003e\n\u003cli\u003eNo diesel fuel tank included\u003c\/li\u003e\n\u003cli\u003eNo automatic transfer switch included\u003c\/li\u003e\n\u003cli\u003eNo starting batteries included\u003c\/li\u003e\n\u003cli\u003eLocal emissions eligibility\u003c\/li\u003e\n\u003cli\u003eCurrent production lead time\u003c\/li\u003e\n\u003cli\u003eFinal factory-installed options\u003c\/li\u003e\n\u003cli\u003eFreight and unloading requirements\u003c\/li\u003e\n\u003cli\u003eCancellation and return restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Cummins Power Generation\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e C175D6D\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e A061T476\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Agricultural standby power\u003cbr\u003e\u003cstrong\u003eStandby Rating:\u003c\/strong\u003e 175kW\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240V\u003cbr\u003e\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003cbr\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003cbr\u003e\u003cstrong\u003eFuel:\u003c\/strong\u003e Diesel\u003cbr\u003e\u003cstrong\u003eMain Circuit Breaker:\u003c\/strong\u003e 800 amps\u003cbr\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Open-skid generator with no enclosure or fuel tank\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSpecifications, availability and standard factory equipment are subject to change. Product images may show optional equipment or a representative configuration. The final Cummins order acknowledgment and order-specific submittal documents determine the exact equipment supplied.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":45297401856115,"sku":"A061T476","price":40288.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/2359\/7385\/files\/cummins-a061t476-open-skid-generator.jpg?v=1785522435","url":"https:\/\/allprogenerators.com\/products\/cummins-c175d6d-175kw-agriculture-generator-a061t476","provider":"AllProGenerators","version":"1.0","type":"link"}