{"product_id":"cummins-c200d6d-200kw-agriculture-generator-a061t477","title":"Cummins C200D6D 200kW Agriculture Diesel Generator 120\/240V 1-Phase | A061T477","description":"\n\u003ch2\u003eCummins C200D6D 200kW Agricultural Diesel Generator\u003c\/h2\u003e\n\n\u003cp\u003eProtect critical farm operations during utility outages with the \u003cstrong\u003eCummins C200D6D 200kW Agricultural Diesel Generator\u003c\/strong\u003e. Cummins part number \u003cstrong\u003eA061T477\u003c\/strong\u003e is a factory-configured agricultural standby generator designed for large farms, dairies, poultry houses, livestock operations, irrigation systems, grain facilities, greenhouses, cold-storage buildings and other agricultural applications requiring high-capacity 120\/240-volt single-phase backup power.\u003c\/p\u003e\n\n\u003cp\u003eThis heavy-duty diesel generator delivers \u003cstrong\u003e200kW of emergency standby power\u003c\/strong\u003e at \u003cstrong\u003e120\/240V single phase\u003c\/strong\u003e. It combines a Cummins QSB7 industrial diesel engine, a brushless four-pole alternator, Cummins PowerCommand electronic controls and an \u003cstrong\u003e800-amp adjustable main circuit breaker\u003c\/strong\u003e in an open-skid agricultural configuration.\u003c\/p\u003e\n\n\u003cdiv style=\"padding:16px; margin:20px 0; border:2px solid #b42318; background-color:#fff5f5;\"\u003e\n  \u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eImportant Agricultural Configuration Notice\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eCummins A061T477 is an open generator set. It does not include a weather enclosure, sound-attenuated enclosure or diesel fuel tank.\u003c\/strong\u003e It requires a properly designed generator building or separately purchased enclosure, an external diesel fuel system, two starting batteries, transfer equipment and professional installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003e200kW Standby Power for Large Agricultural Operations\u003c\/h2\u003e\n\n\u003cp\u003eModern agricultural facilities rely on electrical power for ventilation, refrigeration, irrigation, milking systems, feeding equipment, grain handling, water pumps, lighting, climate controls and automated production equipment. A prolonged power outage can quickly threaten livestock health, stored crops, refrigerated products and daily farm operations.\u003c\/p\u003e\n\n\u003cp\u003eThe Cummins C200D6D is designed to provide dependable emergency power and rapid response as electrical loads start or change. Its high-capacity 120\/240V single-phase output makes it a strong option for large farms and rural facilities with substantial single-phase electrical services.\u003c\/p\u003e\n\n\u003cp\u003eWhen connected to a properly selected automatic transfer switch, the generator can start automatically after a utility failure and provide power to approved agricultural loads until utility service is restored.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e200kW emergency standby power rating\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase electrical output\u003c\/li\u003e\n  \u003cli\u003e60 Hz operating frequency\u003c\/li\u003e\n  \u003cli\u003e800-amp adjustable main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCummins QSB7 industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e6.69-liter heavy-duty engine displacement\u003c\/li\u003e\n  \u003cli\u003eTurbocharged and charge-air-cooled operation\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM rated engine speed\u003c\/li\u003e\n  \u003cli\u003eCummins PowerCommand electronic control system\u003c\/li\u003e\n  \u003cli\u003eAutomatic remote-start and stop capability\u003c\/li\u003e\n  \u003cli\u003eBattle Short Mode\u003c\/li\u003e\n  \u003cli\u003eFlexible generator exercise scheduling\u003c\/li\u003e\n  \u003cli\u003eIntegrated generator protection and diagnostics\u003c\/li\u003e\n  \u003cli\u003eBrushless four-pole alternator\u003c\/li\u003e\n  \u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n  \u003cli\u003eLess than 5% total harmonic distortion with linear loads\u003c\/li\u003e\n  \u003cli\u003eHigh-ambient liquid-cooling system\u003c\/li\u003e\n  \u003cli\u003eCoolant heaters for improved cold-weather starting\u003c\/li\u003e\n  \u003cli\u003eUL 2200 agricultural generator configuration\u003c\/li\u003e\n  \u003cli\u003eOpen-skid construction with no enclosure or fuel tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCummins QSB7 Industrial Diesel Engine\u003c\/h2\u003e\n\n\u003cp\u003eThe C200D6D agricultural generator is powered by the \u003cstrong\u003eCummins QSB7\u003c\/strong\u003e, a rugged 6.69-liter industrial diesel engine engineered for stationary power-generation applications.\u003c\/p\u003e\n\n\u003cp\u003eThe heavy-duty four-cycle engine uses turbocharging and charge-air cooling to provide dependable power and quick response when large agricultural loads start or change. Its 1,800 RPM operating speed is designed for stationary standby-generator service.\u003c\/p\u003e\n\n\u003cp\u003eCast-iron construction, liquid cooling, a spin-on oil filter and a 100-amp engine-driven battery-charging alternator help support reliable emergency operation when the generator is correctly installed, exercised and maintained.\u003c\/p\u003e\n\n\u003ch3\u003eEngine Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins QSB7 diesel engine\u003c\/li\u003e\n  \u003cli\u003e6.69-liter displacement\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty cast-iron construction\u003c\/li\u003e\n  \u003cli\u003eFour-cycle industrial design\u003c\/li\u003e\n  \u003cli\u003eTurbocharged and charge-air cooled\u003c\/li\u003e\n  \u003cli\u003eLiquid-cooled operation\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM rated speed\u003c\/li\u003e\n  \u003cli\u003e100-amp engine-driven battery-charging alternator\u003c\/li\u003e\n  \u003cli\u003eSpin-on oil filter with pressure-relief valve\u003c\/li\u003e\n  \u003cli\u003eFast response to changing electrical loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCummins PowerCommand Electronic Control\u003c\/h2\u003e\n\n\u003cp\u003eThe integrated \u003cstrong\u003eCummins PowerCommand\u003c\/strong\u003e control system coordinates engine, alternator and generator-protection functions. It supports automatic operation when the generator is connected to compatible transfer equipment and provides the monitoring, regulation and protection required for critical agricultural standby applications.\u003c\/p\u003e\n\n\u003ch3\u003ePowerCommand Control Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAutomatic remote starting and stopping\u003c\/li\u003e\n  \u003cli\u003ePrecise voltage regulation\u003c\/li\u003e\n  \u003cli\u003ePrecise frequency regulation\u003c\/li\u003e\n  \u003cli\u003eGenerator output metering\u003c\/li\u003e\n  \u003cli\u003eEngine and generator status monitoring\u003c\/li\u003e\n  \u003cli\u003eAlarm and operating-status messages\u003c\/li\u003e\n  \u003cli\u003eAutomatic shutdown when qualifying faults are detected\u003c\/li\u003e\n  \u003cli\u003eIntegrated generator-set protection\u003c\/li\u003e\n  \u003cli\u003eSelf-diagnostic capabilities\u003c\/li\u003e\n  \u003cli\u003eNFPA 110 Level 1 control functionality\u003c\/li\u003e\n  \u003cli\u003eProgrammable exercise scheduling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBattle Short Mode\u003c\/h2\u003e\n\n\u003cp\u003eBattle Short Mode allows selected protective shutdowns to be overridden when maintaining electrical power is considered more important than protecting the generator from possible damage.\u003c\/p\u003e\n\n\u003cp\u003eThis feature can be important during agricultural emergencies where the immediate loss of ventilation, refrigeration, irrigation, water pumps, feeding systems or environmental controls could endanger livestock, crops or stored products.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBattle Short Mode must only be used by qualified personnel and in accordance with Cummins operating instructions.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFlexible Generator Exercise Scheduling\u003c\/h2\u003e\n\n\u003cp\u003eRoutine generator exercise helps verify that the engine, starting system, alternator and controls are prepared for a utility outage. Cummins flexible exercise scheduling allows the operating time, frequency and duration to be programmed around the needs of the agricultural facility.\u003c\/p\u003e\n\n\u003cp\u003eA properly planned exercise schedule can help reduce unnecessary diesel consumption, emissions and noise while keeping the generator prepared for emergency operation.\u003c\/p\u003e\n\n\u003ch2\u003eBrushless Alternator Performance\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins alternator uses a brushless, four-pole revolving-field design with low-reactance 2\/3-pitch windings. This configuration helps provide stable voltage, low waveform distortion and dependable motor-starting performance for demanding agricultural loads.\u003c\/p\u003e\n\n\u003ch3\u003eAlternator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eBrushless four-pole alternator\u003c\/li\u003e\n  \u003cli\u003eDrip-proof revolving-field design\u003c\/li\u003e\n  \u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n  \u003cli\u003eDirect-coupled rotor\u003c\/li\u003e\n  \u003cli\u003eAutomatic voltage regulation\u003c\/li\u003e\n  \u003cli\u003eLess than 5% total harmonic distortion from no load to full linear load\u003c\/li\u003e\n  \u003cli\u003eLess than 3% distortion for any single harmonic\u003c\/li\u003e\n  \u003cli\u003eShort-circuit fault-clearing capability\u003c\/li\u003e\n  \u003cli\u003eSelectable motor-starting capability\u003c\/li\u003e\n  \u003cli\u003eDirect-drive centrifugal cooling blower\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHigh-Ambient Cooling System\u003c\/h2\u003e\n\n\u003cp\u003eThe standard generator cooling package is designed to support operation in ambient temperatures up to 50°C or 122°F under applicable Cummins operating and derating conditions.\u003c\/p\u003e\n\n\u003cp\u003eProper installation must provide adequate combustion air, radiator airflow and hot-air discharge. Agricultural dust, debris and restricted airflow can reduce cooling performance and must be considered during site design.\u003c\/p\u003e\n\n\u003cp\u003eCoolant heaters are supplied with the agricultural configuration to support reliable cold-weather starting when they are correctly powered and installed.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Agricultural Applications\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eLarge dairy farms and automated milking systems\u003c\/li\u003e\n  \u003cli\u003ePoultry houses and high-capacity ventilation equipment\u003c\/li\u003e\n  \u003cli\u003eLivestock barns and environmental controls\u003c\/li\u003e\n  \u003cli\u003eAutomated feeding and watering systems\u003c\/li\u003e\n  \u003cli\u003eLarge irrigation pumps and agricultural wells\u003c\/li\u003e\n  \u003cli\u003eGreenhouses and climate-control systems\u003c\/li\u003e\n  \u003cli\u003eGrain elevators and material-handling systems\u003c\/li\u003e\n  \u003cli\u003eGrain drying and storage facilities\u003c\/li\u003e\n  \u003cli\u003eProduce refrigeration and cold storage\u003c\/li\u003e\n  \u003cli\u003eFarm shops and equipment buildings\u003c\/li\u003e\n  \u003cli\u003eAgricultural processing equipment\u003c\/li\u003e\n  \u003cli\u003eFood-production and packaging facilities\u003c\/li\u003e\n  \u003cli\u003eLarge rural properties with single-phase service\u003c\/li\u003e\n  \u003cli\u003eEmergency power for critical farm infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMotor Starting and Generator Sizing\u003c\/h2\u003e\n\n\u003cp\u003eAgricultural facilities frequently operate irrigation pumps, ventilation fans, refrigeration compressors, augers, conveyors, grain dryers and other motors that can draw substantially more current during startup than during normal operation.\u003c\/p\u003e\n\n\u003cp\u003eGenerator selection should not be based only on total running wattage. A proper engineering analysis should consider motor horsepower, locked-rotor current, starting method, voltage drop, load sequencing, simultaneous operation, elevation, ambient temperature and future expansion.\u003c\/p\u003e\n\n\u003cp\u003eA qualified generator professional or electrical engineer should complete a detailed load and motor-starting analysis before the generator is ordered.\u003c\/p\u003e\n\n\u003ch2\u003eUnderstanding the 800-Amp Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eA 200kW load at 240V single phase mathematically corresponds to approximately 833 amps. The A061T477 agricultural package is listed with an \u003cstrong\u003e800-amp adjustable main circuit breaker\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe final usable output, breaker settings, conductor sizing and load-management strategy must be determined from the order-specific Cummins submittal and by the engineer or electrician responsible for the installation. Do not size transfer equipment or conductors from the nominal kW rating alone.\u003c\/p\u003e\n\n\u003ch2\u003eOpen-Skid Agricultural Configuration\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eCummins A061T477 does not include a weather-protective or sound-attenuated enclosure.\u003c\/strong\u003e The engine, radiator, alternator, controller and other generator components remain exposed on the structural skid.\u003c\/p\u003e\n\n\u003cp\u003eThe generator must be installed inside a properly designed generator room, agricultural equipment building or compatible separately purchased enclosure. The installation must provide adequate ventilation, combustion air, radiator discharge, weather protection, exhaust routing, service access and protection from unauthorized personnel.\u003c\/p\u003e\n\n\u003cp\u003eDo not order this model expecting an enclosed outdoor generator. Cummins and distributor images may display optional equipment or representative configurations that are not included with A061T477.\u003c\/p\u003e\n\n\u003ch2\u003eNo Diesel Fuel Tank Included\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eThis generator does not include an onboard, belly-mounted or sub-base diesel fuel tank.\u003c\/strong\u003e A properly sized external diesel fuel tank or compatible separately purchased sub-base tank must be provided as part of the installation.\u003c\/p\u003e\n\n\u003cp\u003eThe fuel system must account for desired emergency runtime, fuel consumption, supply and return piping, maximum fuel lift, filtration, containment, fuel quality and applicable fire and environmental regulations.\u003c\/p\u003e\n\n\u003ch2\u003eAutomatic Transfer Switch Not Included\u003c\/h2\u003e\n\n\u003cp\u003eAn automatic transfer switch is not included. Approved transfer equipment is required for automatic backup of a building or electrical service.\u003c\/p\u003e\n\n\u003cp\u003eThe transfer switch must match the facility's 120\/240V single-phase electrical service, required amperage, service-entrance arrangement and applicable codes. Depending on the application, an 800-amp transfer switch or a separately engineered distribution and load-management system may be required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNever connect the generator directly to utility-supplied wiring without approved transfer equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eStarting Batteries Required\u003c\/h2\u003e\n\n\u003cp\u003eThe C200D6D agricultural generator requires \u003cstrong\u003etwo 12-volt starting batteries rated at approximately 850 cold-cranking amps each\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eStarting batteries are not included. Battery cables and an external battery charger are also not included unless specifically listed on the final sales order.\u003c\/p\u003e\n\n\u003ch2\u003eCummins C200D6D A061T477 Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins Power Generation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eC200D6D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA061T477\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAgricultural Spec Diesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEmergency agricultural standby power\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandby Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrime Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot marketed for prime power in this agricultural configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120\/240V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalculated Full-Load Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 833 amps at 200kW and 240V single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMain Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e800 amps, adjustable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDiesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSB7\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Displacement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.69 liters \/ 6,690 cc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHeavy-duty four-cycle industrial diesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAspiration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTurbocharged and charge-air cooled\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Engine Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,800 RPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLiquid cooled with set-mounted radiator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling-System Ambient Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 50°C \/ 122°F under applicable Cummins conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoolant Heaters\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded with the agricultural configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Battery-Charging Alternator\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGenerator Controller\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins PowerCommand electronic control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic or manual electric start\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Battery Requirement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwo 12V batteries rated at approximately 850 CCA each\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Batteries Included\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternator Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrushless four-pole revolving field\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternator Windings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow-reactance 2\/3-pitch windings\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 5% from no load to full linear load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Product Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e113 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Product Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Product Height\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e56 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Product Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3,491 pounds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUL Listing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUL 2200 agricultural configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEmissions Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eU.S. EPA stationary emergency application\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBattle Short Mode\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFlexible Exercise Scheduling\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeather Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSound Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiesel Fuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAutomatic Transfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOpen structural skid\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalifornia Availability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVerify current emissions eligibility before ordering\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProfessional installation required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins C200D6D agricultural diesel generator set\u003c\/li\u003e\n  \u003cli\u003eCummins QSB7 industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase alternator\u003c\/li\u003e\n  \u003cli\u003eCummins PowerCommand electronic control system\u003c\/li\u003e\n  \u003cli\u003e800-amp adjustable main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eSet-mounted radiator and liquid-cooling system\u003c\/li\u003e\n  \u003cli\u003eCoolant heaters\u003c\/li\u003e\n  \u003cli\u003eOpen structural generator skid\u003c\/li\u003e\n  \u003cli\u003eStandard factory equipment associated with A061T477\u003c\/li\u003e\n  \u003cli\u003eCummins manufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat Is Not Included\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eWeather-protective enclosure\u003c\/li\u003e\n  \u003cli\u003eSound-attenuated enclosure\u003c\/li\u003e\n  \u003cli\u003eIntegrated, belly-mounted or sub-base diesel fuel tank\u003c\/li\u003e\n  \u003cli\u003eAutomatic transfer switch\u003c\/li\u003e\n  \u003cli\u003eTwo required 12V starting batteries\u003c\/li\u003e\n  \u003cli\u003eBattery cables or external battery charger unless listed\u003c\/li\u003e\n  \u003cli\u003eConcrete generator pad or engineered foundation\u003c\/li\u003e\n  \u003cli\u003eExternal exhaust piping and installation\u003c\/li\u003e\n  \u003cli\u003eFuel lines, fuel filtration or fuel-system installation\u003c\/li\u003e\n  \u003cli\u003eElectrical wiring and installation materials\u003c\/li\u003e\n  \u003cli\u003ePermits, engineering or site preparation\u003c\/li\u003e\n  \u003cli\u003eGenerator building or separately purchased enclosure\u003c\/li\u003e\n  \u003cli\u003eForklift, crane or unloading services\u003c\/li\u003e\n  \u003cli\u003eStartup or commissioning unless purchased separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eProfessional Installation Required\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C200D6D must be installed by qualified generator, electrical, mechanical, exhaust and fuel-system professionals. The completed installation must comply with Cummins requirements and all applicable national, state and local electrical, fire, fuel, emissions, environmental and building codes.\u003c\/p\u003e\n\n\u003cp\u003eInstallation planning should address:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eComplete electrical-load analysis\u003c\/li\u003e\n  \u003cli\u003eMotor-starting and locked-rotor current\u003c\/li\u003e\n  \u003cli\u003eLoad sequencing and load management\u003c\/li\u003e\n  \u003cli\u003eAutomatic transfer-switch sizing\u003c\/li\u003e\n  \u003cli\u003eBreaker coordination and conductor sizing\u003c\/li\u003e\n  \u003cli\u003eFoundation and vibration isolation\u003c\/li\u003e\n  \u003cli\u003eWeather protection for the open generator\u003c\/li\u003e\n  \u003cli\u003eCombustion air and radiator airflow\u003c\/li\u003e\n  \u003cli\u003eExhaust routing and permissible backpressure\u003c\/li\u003e\n  \u003cli\u003eDiesel fuel storage and containment\u003c\/li\u003e\n  \u003cli\u003eGrounding and electrical protection\u003c\/li\u003e\n  \u003cli\u003eStarting batteries and battery charging\u003c\/li\u003e\n  \u003cli\u003eMaintenance and service clearances\u003c\/li\u003e\n  \u003cli\u003eEmergency shutdown requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFreight Shipping and Delivery\u003c\/h2\u003e\n\n\u003cp\u003eThis commercial agricultural generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the generator.\u003c\/p\u003e\n\n\u003cp\u003eA properly rated forklift, crane or other lifting equipment will normally be required. Standard liftgate service may not be available or sufficient for unloading a generator weighing approximately 3,491 pounds.\u003c\/p\u003e\n\n\u003cp\u003eFarm delivery, residential delivery, limited-access service, jobsite delivery, storage, redelivery, reconsignment and other special freight services may result in additional charges.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInspect the generator and shipping materials before signing the delivery receipt.\u003c\/strong\u003e Any visible damage, missing components or packaging concerns must be clearly documented on the carrier's delivery receipt at the time of delivery.\u003c\/p\u003e\n\n\u003ch2\u003eCummins Limited Warranty\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C200D6D A061T477 is covered by the applicable \u003cstrong\u003eCummins two-year limited generator-set warranty\u003c\/strong\u003e. Some published product listings describe this as two years or 1,000 operating hours, subject to the official Cummins warranty terms.\u003c\/p\u003e\n\n\u003cp\u003eWarranty coverage is subject to Cummins application requirements, operating-hour limits, maintenance requirements and exclusions. The generator should be registered after installation, and authorized startup or documented maintenance may be required.\u003c\/p\u003e\n\n\u003cp\u003eRefer to the Cummins limited warranty statement supplied with the generator for the complete and controlling warranty terms.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eIs A061T477 the agricultural version of the Cummins C200D6D?\u003c\/h3\u003e\n\u003cp\u003eYes. A061T477 is the agricultural-spec Cummins C200D6D configured for 200kW of emergency standby power at 120\/240V single phase.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this generator include an enclosure?\u003c\/h3\u003e\n\u003cp\u003eNo. It is an open-skid generator without a weather-protective or sound-attenuated enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eCan the generator be installed outdoors as delivered?\u003c\/h3\u003e\n\u003cp\u003eNo. The exposed generator requires a properly engineered equipment building or compatible separately purchased weather enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eDoes A061T477 include a diesel fuel tank?\u003c\/h3\u003e\n\u003cp\u003eNo. It does not include an onboard, belly-mounted or sub-base fuel tank. A properly sized external diesel fuel system is required.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it include an automatic transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. Transfer equipment must be purchased separately and selected for the facility's voltage, phase, service amperage and applicable code requirements.\u003c\/p\u003e\n\n\u003ch3\u003eHow much standby power does the C200D6D produce?\u003c\/h3\u003e\n\u003cp\u003eThe A061T477 agricultural configuration is rated for 200kW of emergency standby power.\u003c\/p\u003e\n\n\u003ch3\u003eWhat voltage and phase does it produce?\u003c\/h3\u003e\n\u003cp\u003eIt produces 120\/240V single-phase, 60 Hz electrical power.\u003c\/p\u003e\n\n\u003ch3\u003eHow many amps does a 200kW single-phase generator produce?\u003c\/h3\u003e\n\u003cp\u003eA 200kW load at 240V single phase mathematically corresponds to approximately 833 amps. The A061T477 package is listed with an 800-amp adjustable main breaker, so the order-specific Cummins submittal and electrical engineering must be used for final load, breaker and conductor sizing.\u003c\/p\u003e\n\n\u003ch3\u003eWhat engine is installed in the generator?\u003c\/h3\u003e\n\u003cp\u003eThe C200D6D uses a Cummins QSB7 6.69-liter industrial diesel engine operating at 1,800 RPM.\u003c\/p\u003e\n\n\u003ch3\u003eAre starting batteries included?\u003c\/h3\u003e\n\u003cp\u003eNo. The generator requires two 12V starting batteries rated at approximately 850 cold-cranking amps each. Batteries are not included unless specifically stated on the final sales order.\u003c\/p\u003e\n\n\u003ch3\u003eCan this generator power an entire farm?\u003c\/h3\u003e\n\u003cp\u003eIt may support a substantial portion of a large farm's electrical load, but a professional load and motor-starting analysis is required before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCan it start large irrigation pumps?\u003c\/h3\u003e\n\u003cp\u003ePotentially. Suitability depends on pump horsepower, motor voltage, locked-rotor current, starting method, wiring distance and other equipment operating simultaneously.\u003c\/p\u003e\n\n\u003ch3\u003eCan it power grain dryers or grain-handling equipment?\u003c\/h3\u003e\n\u003cp\u003ePotentially, but grain dryers, augers, elevators and fans may have significant starting loads. The complete system must be evaluated before selecting the generator.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is PowerCommand?\u003c\/h3\u003e\n\u003cp\u003ePowerCommand is Cummins' integrated electronic generator-control system. It manages remote starting, voltage and frequency regulation, output metering, fault protection and system diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is Battle Short Mode?\u003c\/h3\u003e\n\u003cp\u003eBattle Short Mode allows selected protective shutdowns to be overridden when maintaining power is considered more critical than protecting the generator from possible damage.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the generator exercise automatically?\u003c\/h3\u003e\n\u003cp\u003eYes. The control system provides flexible exercise scheduling that can be programmed for the preferred time, duration and frequency.\u003c\/p\u003e\n\n\u003ch3\u003eIs this generator intended for prime power?\u003c\/h3\u003e\n\u003cp\u003eThis specific A061T477 agricultural package is marketed for stationary emergency standby applications. Do not use or advertise it for prime power without written application approval from Cummins.\u003c\/p\u003e\n\n\u003ch3\u003eWhat are the approximate generator dimensions?\u003c\/h3\u003e\n\u003cp\u003eThe open generator is approximately 113 inches long, 40 inches wide and 56 inches high. Use the order-specific Cummins outline drawing for final foundation and installation planning.\u003c\/p\u003e\n\n\u003ch3\u003eHow much does the generator weigh?\u003c\/h3\u003e\n\u003cp\u003eThe published product weight is approximately 3,491 pounds. Confirm the final shipping weight before arranging unloading equipment.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it include coolant heaters?\u003c\/h3\u003e\n\u003cp\u003eYes. Coolant heaters are listed as standard on the agricultural generator configuration to support reliable cold-weather starting when properly powered and installed.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the generator require professional installation?\u003c\/h3\u003e\n\u003cp\u003eYes. Professional generator, electrical, mechanical, exhaust and fuel-system installation is required.\u003c\/p\u003e\n\n\u003ch3\u003eCan the product image show equipment that is not included?\u003c\/h3\u003e\n\u003cp\u003eYes. Manufacturer and distributor images may show representative configurations or optional equipment. A061T477 is sold as an open generator without an enclosure or fuel tank.\u003c\/p\u003e\n\n\u003ch3\u003eWhat transfer-switch size is required?\u003c\/h3\u003e\n\u003cp\u003eThe transfer-switch size depends on the service configuration, engineered load, breaker setting, conductor sizing and applicable electrical codes. Do not select transfer equipment solely from the 200kW nameplate rating.\u003c\/p\u003e\n\n\u003ch3\u003eWhat warranty is included?\u003c\/h3\u003e\n\u003cp\u003eThe generator is covered by the applicable Cummins two-year limited generator-set warranty, subject to the official terms, operating-hour limits and application requirements.\u003c\/p\u003e\n\n\u003ch2\u003eImportant Ordering Information\u003c\/h2\u003e\n\n\u003cp\u003eCommercial generators may be factory built, configured or allocated for a specific customer order. Confirm the following before purchasing:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins part number A061T477\u003c\/li\u003e\n  \u003cli\u003eC200D6D agricultural configuration\u003c\/li\u003e\n  \u003cli\u003e200kW standby rating\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase output\u003c\/li\u003e\n  \u003cli\u003e800-amp adjustable circuit breaker\u003c\/li\u003e\n  \u003cli\u003eOpen generator configuration\u003c\/li\u003e\n  \u003cli\u003eNo enclosure included\u003c\/li\u003e\n  \u003cli\u003eNo diesel fuel tank included\u003c\/li\u003e\n  \u003cli\u003eNo automatic transfer switch included\u003c\/li\u003e\n  \u003cli\u003eNo starting batteries included\u003c\/li\u003e\n  \u003cli\u003eLocal emissions eligibility\u003c\/li\u003e\n  \u003cli\u003eCurrent production lead time\u003c\/li\u003e\n  \u003cli\u003eFinal factory-installed options\u003c\/li\u003e\n  \u003cli\u003eOrder-specific electrical ratings\u003c\/li\u003e\n  \u003cli\u003eFreight and unloading requirements\u003c\/li\u003e\n  \u003cli\u003eCancellation and return restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Cummins Power Generation\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e C200D6D\u003cbr\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e A061T477\u003cbr\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Agricultural standby power\u003cbr\u003e\n\u003cstrong\u003eStandby Rating:\u003c\/strong\u003e 200kW\u003cbr\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240V\u003cbr\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003cbr\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003cbr\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Diesel\u003cbr\u003e\n\u003cstrong\u003eMain Circuit Breaker:\u003c\/strong\u003e 800 amps, adjustable\u003cbr\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Open-skid generator with no enclosure or fuel tank\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications, availability and standard factory equipment are subject to change. Product images may show optional equipment or a representative configuration. The final Cummins order acknowledgment and order-specific submittal documents determine the exact equipment supplied.\u003c\/em\u003e\u003c\/p\u003e\n","brand":"Cummins","offers":[{"title":"Default Title","offer_id":45297609506931,"sku":"A061T477","price":44405.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/2359\/7385\/files\/cummins-c200d6d-200kw-agriculture-generator.jpg?v=1785522494","url":"https:\/\/allprogenerators.com\/products\/cummins-c200d6d-200kw-agriculture-generator-a061t477","provider":"AllProGenerators","version":"1.0","type":"link"}