{"product_id":"cummins-c30d6-30kw-enclosed-diesel-generator","title":"Cummins C30D6 30kW Enclosed Diesel Generator 120\/240V Single Phase | Tank Options","description":"\u003ch2\u003eCummins C30D6 30kW Enclosed Diesel Generator\u003c\/h2\u003e\n\n\u003cp\u003eProtect your home, farm, business or light-commercial facility with the \u003cstrong\u003eCummins C30D6 30kW Enclosed Diesel Generator\u003c\/strong\u003e. This heavy-duty standby generator delivers dependable \u003cstrong\u003e120\/240V single-phase power\u003c\/strong\u003e and is available in two factory-configured options:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA063P964:\u003c\/strong\u003e Sound Level 1 enclosed generator without a fuel tank\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA063P963:\u003c\/strong\u003e Sound Level 1 enclosed generator with a 74-gallon basic sub-base fuel tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eBoth configurations provide \u003cstrong\u003e30kW of standby power\u003c\/strong\u003e and \u003cstrong\u003e27kW of prime power\u003c\/strong\u003e. The C30D6 combines a Cummins 3.3-liter industrial diesel engine, brushless four-pole alternator, PowerCommand 1.1 electronic controls, a 150-amp main circuit breaker and a weather-protective aluminum enclosure in a complete stationary power package.\u003c\/p\u003e\n\n\u003cdiv style=\"padding:16px; margin:20px 0; border:2px solid #b42318; background-color:#fff5f5;\"\u003e\n  \u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eImportant Fuel-Tank Selection\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eChoose the correct configuration before ordering.\u003c\/strong\u003e A063P964 includes the enclosed generator but does not include a diesel fuel tank. A063P963 includes the enclosed generator mounted on a 74-gallon basic sub-base diesel tank. The two configurations have different overall heights, weights and installation requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAvailable Configurations\u003c\/h2\u003e\n\n\u003ch3\u003eA063P964 — Enclosed Generator Without Fuel Tank\u003c\/h3\u003e\n\n\u003cp\u003eCummins part number \u003cstrong\u003eA063P964\u003c\/strong\u003e includes the complete C30D6 generator set with a Sound Level 1 weather-protective enclosure but \u003cstrong\u003edoes not include a diesel fuel tank\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis option is appropriate when the installation will use an existing external diesel tank, a separately selected fuel-storage system or a custom fuel arrangement designed for the required runtime and local codes.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e30kW standby output\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase power\u003c\/li\u003e\n  \u003cli\u003eSound Level 1 aluminum enclosure\u003c\/li\u003e\n  \u003cli\u003e150-amp circuit breaker\u003c\/li\u003e\n  \u003cli\u003eNo integrated or sub-base fuel tank\u003c\/li\u003e\n  \u003cli\u003eExternal fuel system required\u003c\/li\u003e\n  \u003cli\u003eApproximate dimensions: 93.8 × 34 × 45.5 inches\u003c\/li\u003e\n  \u003cli\u003eApproximate weight: 1,282 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA063P963 — Enclosed Generator With 24-Hour Basic Tank\u003c\/h3\u003e\n\n\u003cp\u003eCummins part number \u003cstrong\u003eA063P963\u003c\/strong\u003e includes the enclosed C30D6 generator mounted on a \u003cstrong\u003e74-gallon basic sub-base diesel fuel tank\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe tank is commonly identified as a 24-hour basic tank because its capacity supports approximately one day of operation under heavy generator loading. Published data indicates approximately \u003cstrong\u003e45.6 hours of runtime at 50% load\u003c\/strong\u003e. Actual runtime varies according to electrical demand, fuel level, ambient conditions and generator condition.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e30kW standby output\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase power\u003c\/li\u003e\n  \u003cli\u003eSound Level 1 aluminum enclosure\u003c\/li\u003e\n  \u003cli\u003e150-amp circuit breaker\u003c\/li\u003e\n  \u003cli\u003e74-gallon metal sub-base diesel tank\u003c\/li\u003e\n  \u003cli\u003eApproximately 24 hours of runtime under heavy loading\u003c\/li\u003e\n  \u003cli\u003eUp to approximately 45.6 hours at 50% load\u003c\/li\u003e\n  \u003cli\u003eApproximate dimensions: 93.8 × 34 × 60.5 inches\u003c\/li\u003e\n  \u003cli\u003eApproximate weight: 1,738 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e30kW Standby Power for Residential and Light-Commercial Applications\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C30D6 is designed to supply dependable backup power when utility service fails. When connected to a properly selected automatic transfer switch, the generator can automatically start, accept the approved electrical load and continue operating until utility power is restored.\u003c\/p\u003e\n\n\u003cp\u003eIts 120\/240V single-phase output makes it suitable for larger homes, farms, workshops, small businesses, offices, rural properties and other facilities with single-phase electrical service.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e30kW emergency standby rating\u003c\/li\u003e\n  \u003cli\u003e27kW prime rating\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase output\u003c\/li\u003e\n  \u003cli\u003e60 Hz operating frequency\u003c\/li\u003e\n  \u003cli\u003e125 amps at the 30kW standby rating\u003c\/li\u003e\n  \u003cli\u003e150-amp main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCummins 3.3-liter industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM engine operation\u003c\/li\u003e\n  \u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n  \u003cli\u003eAutomatic remote-start and stop capability\u003c\/li\u003e\n  \u003cli\u003eFlexible generator exercise scheduling\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostics and fault protection\u003c\/li\u003e\n  \u003cli\u003eBrushless four-pole alternator\u003c\/li\u003e\n  \u003cli\u003eLess than 5% total harmonic distortion\u003c\/li\u003e\n  \u003cli\u003eSound Level 1 weather-protective enclosure\u003c\/li\u003e\n  \u003cli\u003eAluminum enclosure construction\u003c\/li\u003e\n  \u003cli\u003eApproximately 69.7 dB(A) at 23 feet\u003c\/li\u003e\n  \u003cli\u003eCoolant heater for improved cold-weather starting\u003c\/li\u003e\n  \u003cli\u003eAvailable with or without a sub-base fuel tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCummins 3.3-Liter Diesel Engine\u003c\/h2\u003e\n\n\u003cp\u003eThe C30D6 is powered by a Cummins 4BT3.3-G5 industrial diesel engine. This rugged four-cycle engine is designed for stationary power-generation applications and provides quick response when electrical loads start or change.\u003c\/p\u003e\n\n\u003cp\u003eThe liquid-cooled engine operates at 1,800 RPM and uses heavy-duty components designed to support reliable standby operation. A spin-on oil filter with a pressure-relief valve simplifies routine maintenance, while an engine-driven battery-charging alternator helps maintain the starting system during generator operation.\u003c\/p\u003e\n\n\u003ch3\u003eEngine Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins 4BT3.3-G5 industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e3.3-liter displacement\u003c\/li\u003e\n  \u003cli\u003eFour-cycle engine design\u003c\/li\u003e\n  \u003cli\u003eLiquid-cooled operation\u003c\/li\u003e\n  \u003cli\u003e1,800 RPM rated speed\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty construction\u003c\/li\u003e\n  \u003cli\u003eFast response to changing loads\u003c\/li\u003e\n  \u003cli\u003eSpin-on oil filter with pressure-relief valve\u003c\/li\u003e\n  \u003cli\u003eEngine-driven battery-charging alternator\u003c\/li\u003e\n  \u003cli\u003eDesigned for stationary standby and approved prime applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePowerCommand 1.1 Electronic Controls\u003c\/h2\u003e\n\n\u003cp\u003eThe integrated \u003cstrong\u003eCummins PowerCommand 1.1\u003c\/strong\u003e control system coordinates the engine, alternator and generator-protection functions. It supports automatic operation when connected to compatible transfer equipment and provides digital monitoring, regulation and diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003ePowerCommand Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAutomatic remote starting and stopping\u003c\/li\u003e\n  \u003cli\u003ePrecise voltage regulation\u003c\/li\u003e\n  \u003cli\u003ePrecise frequency regulation\u003c\/li\u003e\n  \u003cli\u003eGenerator output metering\u003c\/li\u003e\n  \u003cli\u003eEngine and generator status monitoring\u003c\/li\u003e\n  \u003cli\u003eAlarm and status-message display\u003c\/li\u003e\n  \u003cli\u003eAutomatic fault shutdown\u003c\/li\u003e\n  \u003cli\u003eIntegrated generator protection\u003c\/li\u003e\n  \u003cli\u003eSelf-diagnostic capabilities\u003c\/li\u003e\n  \u003cli\u003eTwo-wire remote-start control\u003c\/li\u003e\n  \u003cli\u003eFlexible generator exercise scheduling\u003c\/li\u003e\n  \u003cli\u003eNFPA 110 Level 1 control capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSound Level 1 Weather-Protective Enclosure\u003c\/h2\u003e\n\n\u003cp\u003eBoth A063P964 and A063P963 include a factory-installed \u003cstrong\u003eSound Level 1 aluminum enclosure\u003c\/strong\u003e. The enclosure protects the generator from normal outdoor weather exposure while helping reduce operating noise.\u003c\/p\u003e\n\n\u003cp\u003ePublished sound data lists operation as low as approximately \u003cstrong\u003e69.7 dB(A) at 23 feet\u003c\/strong\u003e, depending on load, installation, surroundings and measurement conditions.\u003c\/p\u003e\n\n\u003ch3\u003eEnclosure Benefits\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eWeather protection for outdoor installation\u003c\/li\u003e\n  \u003cli\u003eAluminum construction for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eReduced operating sound compared with an open generator\u003c\/li\u003e\n  \u003cli\u003eIntegrated ventilation and cooling-air pathways\u003c\/li\u003e\n  \u003cli\u003eService-access panels\u003c\/li\u003e\n  \u003cli\u003eCompact factory-engineered design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBrushless Alternator Performance\u003c\/h2\u003e\n\n\u003cp\u003eThe C30D6 uses a brushless four-pole alternator with automatic voltage regulation. Low-reactance 2\/3-pitch windings help provide stable electrical output, dependable motor-starting performance and low waveform distortion.\u003c\/p\u003e\n\n\u003ch3\u003eAlternator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eBrushless four-pole design\u003c\/li\u003e\n  \u003cli\u003eDrip-proof revolving field\u003c\/li\u003e\n  \u003cli\u003eLow-reactance 2\/3-pitch windings\u003c\/li\u003e\n  \u003cli\u003eAutomatic voltage regulation\u003c\/li\u003e\n  \u003cli\u003eLess than 5% total harmonic distortion\u003c\/li\u003e\n  \u003cli\u003eLess than 3% distortion for any single harmonic\u003c\/li\u003e\n  \u003cli\u003eShort-circuit fault-clearing capability\u003c\/li\u003e\n  \u003cli\u003eDirect-drive centrifugal cooling blower\u003c\/li\u003e\n  \u003cli\u003eSelectable motor-starting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHigh-Ambient Cooling System\u003c\/h2\u003e\n\n\u003cp\u003eThe set-mounted radiator and liquid-cooling system are designed to support operation in ambient temperatures up to 50°C or 122°F under applicable Cummins rating and derating conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe installation must provide the required airflow and clearances around the enclosure. Landscaping, walls, fences, debris and other obstructions can restrict cooling air or trap hot exhaust air around the generator.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eLarge residential homes\u003c\/li\u003e\n  \u003cli\u003eFarms and rural properties\u003c\/li\u003e\n  \u003cli\u003eSmall businesses\u003c\/li\u003e\n  \u003cli\u003eRetail locations\u003c\/li\u003e\n  \u003cli\u003eProfessional offices\u003c\/li\u003e\n  \u003cli\u003eWorkshops and equipment buildings\u003c\/li\u003e\n  \u003cli\u003eSmall warehouses\u003c\/li\u003e\n  \u003cli\u003eCommunications equipment\u003c\/li\u003e\n  \u003cli\u003eWater and well systems\u003c\/li\u003e\n  \u003cli\u003eRefrigeration equipment\u003c\/li\u003e\n  \u003cli\u003eLight agricultural loads\u003c\/li\u003e\n  \u003cli\u003eEmergency lighting and security systems\u003c\/li\u003e\n  \u003cli\u003eCritical residential electrical systems\u003c\/li\u003e\n  \u003cli\u003eLight-commercial standby power\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat Can a 30kW Generator Power?\u003c\/h2\u003e\n\n\u003cp\u003eA properly sized 30kW generator may support a large residential electrical system or selected light-commercial loads. Potential loads may include:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCentral air-conditioning equipment\u003c\/li\u003e\n  \u003cli\u003eRefrigerators and freezers\u003c\/li\u003e\n  \u003cli\u003eWell and water pumps\u003c\/li\u003e\n  \u003cli\u003eLighting and receptacle circuits\u003c\/li\u003e\n  \u003cli\u003eSecurity and communication systems\u003c\/li\u003e\n  \u003cli\u003eOffice electronics\u003c\/li\u003e\n  \u003cli\u003eGarage or shop equipment\u003c\/li\u003e\n  \u003cli\u003eSelected electric appliances\u003c\/li\u003e\n  \u003cli\u003eSmall commercial refrigeration\u003c\/li\u003e\n  \u003cli\u003eEssential business equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe generator must be sized using actual electrical loads. Motor-starting current, electric heat, water heaters, pumps, air conditioners, compressors and other high-demand equipment can significantly affect generator capacity.\u003c\/p\u003e\n\n\u003ch2\u003eFuel Consumption and Runtime\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOperating Condition\u003c\/th\u003e\n      \u003cth\u003eApproximate Diesel Consumption\u003c\/th\u003e\n      \u003cth\u003eA063P963 Estimated Runtime\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e50% standby load\u003c\/td\u003e\n      \u003ctd\u003eApproximately 1.62 gallons per hour\u003c\/td\u003e\n      \u003ctd\u003eApproximately 45.6 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e100% standby load\u003c\/td\u003e\n      \u003ctd\u003eApproximately 2.81 gallons per hour\u003c\/td\u003e\n      \u003ctd\u003eApproximately 26 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFuel-consumption and runtime figures are approximate. Actual results vary with electrical demand, fuel level, ambient temperature, elevation, fuel quality, maintenance condition and installation.\u003c\/p\u003e\n\n\u003ch2\u003eTank Selection Guidance\u003c\/h2\u003e\n\n\u003ch3\u003eChoose A063P964 Without a Tank When:\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eThe property already has an approved external diesel tank\u003c\/li\u003e\n  \u003cli\u003eA larger custom tank is required for extended runtime\u003c\/li\u003e\n  \u003cli\u003eLocal codes require a specific tank arrangement\u003c\/li\u003e\n  \u003cli\u003eThe installer will provide a remote fuel system\u003c\/li\u003e\n  \u003cli\u003eThe generator must be mounted independently of the tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoose A063P963 With the Basic Tank When:\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eA compact generator-and-tank package is preferred\u003c\/li\u003e\n  \u003cli\u003eApproximately one day of heavy-load runtime is sufficient\u003c\/li\u003e\n  \u003cli\u003eUp to approximately 45.6 hours at 50% load is useful\u003c\/li\u003e\n  \u003cli\u003eA factory-matched 74-gallon sub-base tank simplifies planning\u003c\/li\u003e\n  \u003cli\u003eLocal codes permit the basic sub-base tank configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAutomatic Transfer Switch Not Included\u003c\/h2\u003e\n\n\u003cp\u003eAn automatic transfer switch is not included with either generator option. A properly selected transfer switch is required for automatic backup of a building or electrical service.\u003c\/p\u003e\n\n\u003cp\u003eThe transfer switch must match the 120\/240V single-phase service, required amperage, service-entrance arrangement, grounding method and applicable electrical codes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNever connect the generator directly to utility-supplied wiring without approved transfer equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eStarting Battery Required\u003c\/h2\u003e\n\n\u003cp\u003eA properly sized starting battery is required but is not included unless specifically stated on the final sales order. Battery cables, an external battery charger and cold-weather accessories may also be required depending on the installation.\u003c\/p\u003e\n\n\u003ch2\u003eCummins C30D6 Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins Power Generation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eC30D6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNo-Tank Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA063P964\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTank Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA063P963\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEnclosed residential and light-commercial diesel generator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandby Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30kW \/ 37.5kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrime Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27kW \/ 33.8kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120\/240V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e125 amps at 30kW and 240V single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMain Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDiesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4BT3.3-G5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Displacement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3 liters\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngine Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHeavy-duty four-cycle industrial diesel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Engine Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,800 RPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLiquid cooled with set-mounted radiator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Cooling Ambient\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 50°C \/ 122°F under applicable conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoolant Heater\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGenerator Controller\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCummins PowerCommand 1.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic or manual electric start\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStarting Battery Included\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternator Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrushless four-pole revolving field\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 5% from no load to full linear load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSound Level 1 weather-protective enclosure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Sound Level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.7 dB(A) at 23 feet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P964 Fuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P964 Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 93.8 × 34 × 45.5 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P964 Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 1,282 pounds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P963 Fuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e74-gallon basic sub-base diesel tank\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P963 Runtime at 50% Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 45.6 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P963 Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 93.8 × 34 × 60.5 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA063P963 Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 1,738 pounds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAutomatic Transfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProfessional installation required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eVariant Comparison\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\" border=\"1\" cellpadding=\"8\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eFeature\u003c\/th\u003e\n      \u003cth\u003eA063P964 — No Tank\u003c\/th\u003e\n      \u003cth\u003eA063P963 — 24-Hour Basic Tank\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandby Output\u003c\/td\u003e\n      \u003ctd\u003e30kW\u003c\/td\u003e\n      \u003ctd\u003e30kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage\u003c\/td\u003e\n      \u003ctd\u003e120\/240V single phase\u003c\/td\u003e\n      \u003ctd\u003e120\/240V single phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure\u003c\/td\u003e\n      \u003ctd\u003eSound Level 1 aluminum\u003c\/td\u003e\n      \u003ctd\u003eSound Level 1 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFuel Tank\u003c\/td\u003e\n      \u003ctd\u003eNot included\u003c\/td\u003e\n      \u003ctd\u003e74-gallon sub-base tank\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Height\u003c\/td\u003e\n      \u003ctd\u003e45.5 inches\u003c\/td\u003e\n      \u003ctd\u003e60.5 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Weight\u003c\/td\u003e\n      \u003ctd\u003e1,282 pounds\u003c\/td\u003e\n      \u003ctd\u003e1,738 pounds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBest For\u003c\/td\u003e\n      \u003ctd\u003eExternal or custom fuel systems\u003c\/td\u003e\n      \u003ctd\u003eFactory-matched tank package\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat Is Included With Both Options\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins C30D6 diesel generator set\u003c\/li\u003e\n  \u003cli\u003eCummins 3.3-liter industrial diesel engine\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase alternator\u003c\/li\u003e\n  \u003cli\u003ePowerCommand 1.1 electronic control system\u003c\/li\u003e\n  \u003cli\u003e150-amp main circuit breaker\u003c\/li\u003e\n  \u003cli\u003eSound Level 1 aluminum enclosure\u003c\/li\u003e\n  \u003cli\u003eSet-mounted radiator and cooling system\u003c\/li\u003e\n  \u003cli\u003eCoolant heater\u003c\/li\u003e\n  \u003cli\u003eFactory generator base\u003c\/li\u003e\n  \u003cli\u003eCummins manufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAdditional Equipment Included With A063P963\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e74-gallon basic sub-base diesel fuel tank\u003c\/li\u003e\n  \u003cli\u003eFactory-matched elevated generator mounting arrangement\u003c\/li\u003e\n  \u003cli\u003eStandard tank equipment associated with A063P963\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat Is Not Included\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAutomatic transfer switch\u003c\/li\u003e\n  \u003cli\u003eStarting battery\u003c\/li\u003e\n  \u003cli\u003eBattery cables or external battery charger unless listed\u003c\/li\u003e\n  \u003cli\u003eConcrete generator pad or engineered foundation\u003c\/li\u003e\n  \u003cli\u003eExternal fuel tank for A063P964\u003c\/li\u003e\n  \u003cli\u003eExternal fuel piping and installation\u003c\/li\u003e\n  \u003cli\u003eElectrical wiring and installation materials\u003c\/li\u003e\n  \u003cli\u003ePermits, engineering or site preparation\u003c\/li\u003e\n  \u003cli\u003eForklift, crane or unloading services\u003c\/li\u003e\n  \u003cli\u003eStartup or commissioning unless purchased separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eProfessional Installation Required\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C30D6 must be installed by qualified generator, electrical, exhaust and fuel-system professionals. Installation must comply with Cummins requirements and all applicable national, state and local electrical, fire, fuel, emissions, environmental and building codes.\u003c\/p\u003e\n\n\u003cp\u003eSite planning should address:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eComplete electrical-load analysis\u003c\/li\u003e\n  \u003cli\u003eMotor-starting requirements\u003c\/li\u003e\n  \u003cli\u003eAutomatic transfer-switch sizing\u003c\/li\u003e\n  \u003cli\u003eFoundation and structural support\u003c\/li\u003e\n  \u003cli\u003eRequired enclosure clearances\u003c\/li\u003e\n  \u003cli\u003eCooling-air intake and hot-air discharge\u003c\/li\u003e\n  \u003cli\u003eExhaust clearances\u003c\/li\u003e\n  \u003cli\u003eFuel storage and containment\u003c\/li\u003e\n  \u003cli\u003eTank venting and filling access\u003c\/li\u003e\n  \u003cli\u003eGrounding and electrical protection\u003c\/li\u003e\n  \u003cli\u003eStarting battery and battery charging\u003c\/li\u003e\n  \u003cli\u003eMaintenance and service access\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFreight Shipping and Delivery\u003c\/h2\u003e\n\n\u003cp\u003eThis enclosed diesel generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the selected configuration.\u003c\/p\u003e\n\n\u003cp\u003eA properly rated forklift, crane or other lifting equipment may be required. Standard liftgate service may not be sufficient for either configuration.\u003c\/p\u003e\n\n\u003cp\u003eResidential delivery, limited-access delivery, appointment service, storage, redelivery, reconsignment and other special freight services may result in additional charges.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInspect the generator and packaging before signing the delivery receipt.\u003c\/strong\u003e Any visible damage, missing components or packaging concerns must be clearly documented on the carrier's delivery receipt at delivery.\u003c\/p\u003e\n\n\u003ch2\u003eCummins Limited Warranty\u003c\/h2\u003e\n\n\u003cp\u003eThe Cummins C30D6 is covered by the applicable \u003cstrong\u003eCummins two-year limited generator-set warranty\u003c\/strong\u003e. Extended warranty options may be available depending on the application and purchase terms.\u003c\/p\u003e\n\n\u003cp\u003eWarranty coverage is subject to Cummins application requirements, operating-hour limits, maintenance requirements and exclusions. Product registration, authorized startup or documented maintenance may be required.\u003c\/p\u003e\n\n\u003cp\u003eRefer to the Cummins warranty statement supplied with the generator for the complete and controlling warranty terms.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is the difference between A063P964 and A063P963?\u003c\/h3\u003e\n\u003cp\u003eBoth are enclosed Cummins C30D6 generators with 30kW standby output and 120\/240V single-phase power. A063P964 does not include a fuel tank. A063P963 includes a 74-gallon basic sub-base tank.\u003c\/p\u003e\n\n\u003ch3\u003eAre both options enclosed?\u003c\/h3\u003e\n\u003cp\u003eYes. Both configurations include a Sound Level 1 weather-protective aluminum enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eIs A063P964 an open generator?\u003c\/h3\u003e\n\u003cp\u003eNo. A063P964 includes the enclosure. It is described as “no tank” because it does not include a diesel fuel tank.\u003c\/p\u003e\n\n\u003ch3\u003eDoes A063P963 include a fuel tank?\u003c\/h3\u003e\n\u003cp\u003eYes. It includes a 74-gallon metal sub-base diesel tank.\u003c\/p\u003e\n\n\u003ch3\u003eWhy is A063P963 called a 24-hour tank?\u003c\/h3\u003e\n\u003cp\u003eThe tank is sized to provide approximately one day of operation under heavy loading. Published specifications indicate about 26 hours at full load and approximately 45.6 hours at 50% load.\u003c\/p\u003e\n\n\u003ch3\u003eHow much power does the C30D6 produce?\u003c\/h3\u003e\n\u003cp\u003eThe generator is rated for 30kW standby and 27kW prime power.\u003c\/p\u003e\n\n\u003ch3\u003eWhat voltage does it produce?\u003c\/h3\u003e\n\u003cp\u003eThese configurations produce 120\/240V single-phase, 60 Hz power.\u003c\/p\u003e\n\n\u003ch3\u003eHow many amps does it produce?\u003c\/h3\u003e\n\u003cp\u003eThe 30kW rating corresponds to approximately 125 amps at 240V single phase.\u003c\/p\u003e\n\n\u003ch3\u003eWhat size circuit breaker is included?\u003c\/h3\u003e\n\u003cp\u003eBoth configurations are listed with a 150-amp main circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eWhat engine is used?\u003c\/h3\u003e\n\u003cp\u003eThe C30D6 uses a Cummins 4BT3.3-G5 3.3-liter industrial diesel engine operating at 1,800 RPM.\u003c\/p\u003e\n\n\u003ch3\u003eIs an automatic transfer switch included?\u003c\/h3\u003e\n\u003cp\u003eNo. A compatible transfer switch must be purchased separately.\u003c\/p\u003e\n\n\u003ch3\u003eIs a starting battery included?\u003c\/h3\u003e\n\u003cp\u003eNo. A properly sized starting battery is required but not included unless specifically listed on the sales order.\u003c\/p\u003e\n\n\u003ch3\u003eCan the generator be installed outdoors?\u003c\/h3\u003e\n\u003cp\u003eYes. Both options include a weather-protective enclosure, but all Cummins clearance, foundation, airflow and exhaust requirements must be followed.\u003c\/p\u003e\n\n\u003ch3\u003eHow loud is the C30D6?\u003c\/h3\u003e\n\u003cp\u003ePublished specifications list approximately 69.7 dB(A) at 23 feet. Actual sound varies with load, surroundings and installation.\u003c\/p\u003e\n\n\u003ch3\u003eCan it power an entire home?\u003c\/h3\u003e\n\u003cp\u003eIt may power a large portion or all of some homes, but suitability depends on the actual load, air-conditioning equipment, electric heat, water heating, pumps and motor-starting requirements.\u003c\/p\u003e\n\n\u003ch3\u003eCan it be used for a business?\u003c\/h3\u003e\n\u003cp\u003eYes. It is designed for residential and light-commercial applications, provided the generator is properly sized for the connected loads.\u003c\/p\u003e\n\n\u003ch3\u003eCan A063P964 be connected to a large external tank?\u003c\/h3\u003e\n\u003cp\u003eYes, provided the fuel system is professionally designed and complies with Cummins requirements and applicable codes.\u003c\/p\u003e\n\n\u003ch3\u003eCan the tank on A063P963 provide more than 24 hours?\u003c\/h3\u003e\n\u003cp\u003eYes. At approximately 50% load, published data indicates about 45.6 hours of runtime. Runtime decreases as electrical load increases.\u003c\/p\u003e\n\n\u003ch3\u003eIs the tank double-wall?\u003c\/h3\u003e\n\u003cp\u003eThe configuration is identified as a basic 74-gallon sub-base tank. Confirm tank construction, containment, alarms and local-code compliance from the order-specific Cummins tank submittal before purchasing.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the generator have clean power for electronics?\u003c\/h3\u003e\n\u003cp\u003eThe alternator is listed with less than 5% total harmonic distortion under linear loads, making it suitable for many common electronic loads when properly installed.\u003c\/p\u003e\n\n\u003ch3\u003eIs professional installation required?\u003c\/h3\u003e\n\u003cp\u003eYes. Professional generator, electrical, exhaust and fuel-system installation is required.\u003c\/p\u003e\n\n\u003ch3\u003eWhich option should I choose?\u003c\/h3\u003e\n\u003cp\u003eChoose A063P964 when using an external or custom fuel system. Choose A063P963 when a compact factory-matched generator and 74-gallon sub-base tank package is preferred.\u003c\/p\u003e\n\n\u003ch2\u003eImportant Ordering Information\u003c\/h2\u003e\n\n\u003cp\u003eBefore ordering, confirm:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCummins model C30D6\u003c\/li\u003e\n  \u003cli\u003e30kW standby output\u003c\/li\u003e\n  \u003cli\u003e120\/240V single-phase configuration\u003c\/li\u003e\n  \u003cli\u003e150-amp circuit breaker\u003c\/li\u003e\n  \u003cli\u003eA063P964 without a fuel tank or A063P963 with a 74-gallon basic tank\u003c\/li\u003e\n  \u003cli\u003eSound Level 1 enclosure\u003c\/li\u003e\n  \u003cli\u003eRequired automatic transfer switch\u003c\/li\u003e\n  \u003cli\u003eStarting-battery requirements\u003c\/li\u003e\n  \u003cli\u003eLocal fuel-tank and emissions requirements\u003c\/li\u003e\n  \u003cli\u003eCurrent production lead time\u003c\/li\u003e\n  \u003cli\u003eFinal factory-installed options\u003c\/li\u003e\n  \u003cli\u003eFreight and unloading requirements\u003c\/li\u003e\n  \u003cli\u003eCancellation and return restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Cummins Power Generation\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e C30D6\u003cbr\u003e\n\u003cstrong\u003eStandby Rating:\u003c\/strong\u003e 30kW\u003cbr\u003e\n\u003cstrong\u003ePrime Rating:\u003c\/strong\u003e 27kW\u003cbr\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240V\u003cbr\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003cbr\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003cbr\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Diesel\u003cbr\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Sound Level 1 aluminum enclosure\u003cbr\u003e\n\u003cstrong\u003eNo-Tank Option:\u003c\/strong\u003e A063P964\u003cbr\u003e\n\u003cstrong\u003e24-Hour Basic-Tank Option:\u003c\/strong\u003e A063P963\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications, availability and included factory equipment are subject to change. Product images may display optional equipment or representative configurations. The final Cummins order acknowledgment and order-specific submittal documents determine the exact equipment supplied.\u003c\/em\u003e\u003c\/p\u003e\n","brand":"Cummins","offers":[{"title":"C30D6 No Fuel Tank","offer_id":45297780064371,"sku":"A063P964","price":21753.54,"currency_code":"USD","in_stock":true},{"title":"C30D6 With 24Hour Fuel Tank","offer_id":45297780097139,"sku":"A063P963","price":26088.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/2359\/7385\/files\/cummins-c30d6-a063p964-no-tank.jpg?v=1785529876","url":"https:\/\/allprogenerators.com\/products\/cummins-c30d6-30kw-enclosed-diesel-generator","provider":"AllProGenerators","version":"1.0","type":"link"}