Kubota GL11000 – 11,000 Watt Lowboy II Series Industrial Diesel Generator – The Kubota GL11000 Lowboy II generator saves space and the environment. It is designed to have the minimum possible height while using a vertical diesel engine. Easy one-side maintenance with a large swing-up side panel for quick engine inspection and maintenance. Safety features include automatic engine shutdown if the water temperature is excessive or oil pressure drops below a safe level and double circuit protectors to prevent overcurrent damage. One-point lifting makes it easy to transport all GL series generators.
Kubota Low Boy II Industrial Diesel Generator
- Quieter, more compact & cleaner (EPA Tier II) than the original Low Boy
479cc Kubota Z482 Liquid-Cooled Diesel Engine
- Large capacity oil pan provides oil change intervals of up to 200 hours
Dual-element air filter design for heavy-duty jobs in dusty conditions
- Keyed Electric Start (Battery Included)
The starter safety relay prevents the starter from engaging after start-up
- Compact Design & Easy Maintenance
By direct coupling the engine crankshaft w/ cooling fan
- Simple maintenance of oil, fuel, battery & cooling water on One side
Large Capacity 7.4 Gallon Diesel Fuel Tank
- Provides up to 10 hours @ 100% load on a single fill-up
Monitor Gauges & Automatic Safety Shutdowns
- Easily see when there’s water temperature & oil pressure issues
Double Circuit Breaker Protection (Generator & Receptacle)
- Shuts the engine down to prevent overcurrent damage
Less Noise During Operation (66 dB(A) @ 23′)
- Slower-speed fan, built-in muffler & reduced air intake sound
Plus Forklift pockets, One-Point Lifting Eye & ATS Terminal
1-Year Limited Warranty
Experience the power and reliability of the Kubota GL11000 11000 Watt Lowboy II Series Industrial Diesel Generator. With 11000 watts of pure diesel power, this generator is perfect for industrial use and is built to provide uninterrupted electricity during any emergency. Trust in Kubota's superior engineering for all your energy needs.
SPECIFICATIONS
MODEL | Unit | GL11000 | |
Type | – | Rotating field single-phase AC generator | |
Frequency | Hz | 60 | |
Standby Output | kVA (kW) | 11.0 (11.0) | |
Prime Output | kVA (kW) | 10.0 (10.0) | |
Voltage – Single Phase | V | 120/240 | |
Armature Connection | – | Series | |
Phase / Wire | – | 1/3 | |
Power Factor | – | 1.0 | |
No. of Poles | – | 2 | |
Insulation | Class | Rotor coil; class F, Stator coil; class B | |
Type of Coupling | – | Direct coupled | |
AMPS | |||
Single Phase 120V | A | 83.3 | |
Single Phase 240V | A | 41.7 | |
5-15R (GFCI) | – | N/A | |
5-20RA (GFCI) | – | 2 | |
6-15R | – | N/A | |
L5-30R | – | 1 | |
L6-30R | – | 1 | |
CS-6369 | – | 1 | |
TERMINAL | |||
Terminal | – | Available | |
DIESEL ENGINE | |||
Type | – | Vertical, liquid-cooled, 4-cycle diesel engine |
|
Model | – | D722 | |
No. of Cylinders | – | 3 | |
Bore x Stroke | mm (in.) | 67.0 x 68.0 (2.6 x 2.7) | |
Displacement | L (cu. in.) | 0.719 (43.9) | |
Engine Speed | rpm | 3600 | |
Continuous Rated Output | kW (HP) | 12.2 (16.3) | |
Lubricant (API classification) |
– | Above CD grade | |
Oil Capacity | L (qts.) | 3.4 (0.9) | |
Coolant Capacity | L (qts.) | 4.1 (1.1) | |
Starting System | – | Electric – 12 volt DC | |
SET | |||
Fuel | – | Diesel fuel No.2 (ASTM D975) |
|
Fuel Consumption |
at Full Load | L/h (gal./h) | 4.1 (1.09) |
at 3/4 Load | L/h (gal./h) | 3.3 (0.86) | |
at 1/2 Load | L/h (gal./h) | 2.7 (0.71) | |
at 1/4 Load | L/h (gal./h) | 2.2 (0.59) | |
Fuel Tank Capacity | L (gal.) | 28.0 (7.4) | |
Continous Operation Hours |
at Full Load | h | 7.0 |
at 3/4 Load | h | 8.5 | |
at 1/2 Load | h | 10.4 | |
at 1/4 Load | h | 12.7 | |
Battery (Ah/5h) | – | 55B24R (12V x 36Ah) | |
Dimensions L x W x H |
mm (in.) |
1281 x 618 x 698 (50.4 x 24.3 x 27.5) |
|
Approx. Net Weight | kg (lbs.) | 295 (650) | |
Sound Level (Full Load at 23 ft. [7m]) |
dB (A) | 68 | |
Emergency Stop System | – | In case of abnormal: oil pressure, water temperature, or when the access terminal cover is opened (terminal type only) |
Note regarding oil fill level at oil change: Here’s the update from Kubota Engines. The 722 generator on the GL11000 comes with either a 101mm or a 120mm deep oil pan. (4” or 4.75”). The 101 takes .9 gallons of oil. The 120 takes 1 gallon. If the unit has the 4.75” deep oil pan it requires 1 gallon to fill it to the top mark on the dipstick. The GL11000-USA uses dip stick part #1G304-36410.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
For the first 2 years or 2000 hours you must use factory filters, or you will void warranty. The owner’s manual recommends you change oil and oil filter first 50 hours. After that change the oil every 100 hours and the oil filter every 200 hours.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
Shipping | This item ships to |
Fast Shipping in the USA. Items ship the same or next day We process orders 7 days a week to ensure the fastest shipping possible. All generators are shipped as fast as possible out of several US locations to ensure the fastest delivery. |
||
We Put Our Customers First We have done the research for you to find the best manufacturers with the best warranties. Every unit on our site is covered by a high quality manufacturers warranty. |
||
We offer the absolute lowest price we can offer |
||
We insist that you love our service. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. |
||
Ordering from AllProGenerators.com is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. |
Description
Kubota GL11000 – 11,000 Watt Lowboy II Series Industrial Diesel Generator – The Kubota GL11000 Lowboy II generator saves space and the environment. It is designed to have the minimum possible height while using a vertical diesel engine. Easy one-side maintenance with a large swing-up side panel for quick engine inspection and maintenance. Safety features include automatic engine shutdown if the water temperature is excessive or oil pressure drops below a safe level and double circuit protectors to prevent overcurrent damage. One-point lifting makes it easy to transport all GL series generators.
FEATURES
Kubota Low Boy II Industrial Diesel Generator
- Quieter, more compact & cleaner (EPA Tier II) than the original Low Boy
479cc Kubota Z482 Liquid-Cooled Diesel Engine
- Large capacity oil pan provides oil change intervals of up to 200 hours
Dual-element air filter design for heavy-duty jobs in dusty conditions
- Keyed Electric Start (Battery Included)
The starter safety relay prevents the starter from engaging after start-up
- Compact Design & Easy Maintenance
By direct coupling the engine crankshaft w/ cooling fan
- Simple maintenance of oil, fuel, battery & cooling water on One side
Large Capacity 7.4 Gallon Diesel Fuel Tank
- Provides up to 10 hours @ 100% load on a single fill-up
Monitor Gauges & Automatic Safety Shutdowns
- Easily see when there’s water temperature & oil pressure issues
Double Circuit Breaker Protection (Generator & Receptacle)
- Shuts the engine down to prevent overcurrent damage
Less Noise During Operation (66 dB(A) @ 23′)
- Slower-speed fan, built-in muffler & reduced air intake sound
Plus Forklift pockets, One-Point Lifting Eye & ATS Terminal
1-Year Limited Warranty
Experience the power and reliability of the Kubota GL11000 11000 Watt Lowboy II Series Industrial Diesel Generator. With 11000 watts of pure diesel power, this generator is perfect for industrial use and is built to provide uninterrupted electricity during any emergency. Trust in Kubota's superior engineering for all your energy needs.
SPECIFICATIONS
MODEL | Unit | GL11000 | |
Type | – | Rotating field single-phase AC generator | |
Frequency | Hz | 60 | |
Standby Output | kVA (kW) | 11.0 (11.0) | |
Prime Output | kVA (kW) | 10.0 (10.0) | |
Voltage – Single Phase | V | 120/240 | |
Armature Connection | – | Series | |
Phase / Wire | – | 1/3 | |
Power Factor | – | 1.0 | |
No. of Poles | – | 2 | |
Insulation | Class | Rotor coil; class F, Stator coil; class B | |
Type of Coupling | – | Direct coupled | |
AMPS | |||
Single Phase 120V | A | 83.3 | |
Single Phase 240V | A | 41.7 | |
5-15R (GFCI) | – | N/A | |
5-20RA (GFCI) | – | 2 | |
6-15R | – | N/A | |
L5-30R | – | 1 | |
L6-30R | – | 1 | |
CS-6369 | – | 1 | |
TERMINAL | |||
Terminal | – | Available | |
DIESEL ENGINE | |||
Type | – | Vertical, liquid-cooled, 4-cycle diesel engine |
|
Model | – | D722 | |
No. of Cylinders | – | 3 | |
Bore x Stroke | mm (in.) | 67.0 x 68.0 (2.6 x 2.7) | |
Displacement | L (cu. in.) | 0.719 (43.9) | |
Engine Speed | rpm | 3600 | |
Continuous Rated Output | kW (HP) | 12.2 (16.3) | |
Lubricant (API classification) |
– | Above CD grade | |
Oil Capacity | L (qts.) | 3.4 (0.9) | |
Coolant Capacity | L (qts.) | 4.1 (1.1) | |
Starting System | – | Electric – 12 volt DC | |
SET | |||
Fuel | – | Diesel fuel No.2 (ASTM D975) |
|
Fuel Consumption |
at Full Load | L/h (gal./h) | 4.1 (1.09) |
at 3/4 Load | L/h (gal./h) | 3.3 (0.86) | |
at 1/2 Load | L/h (gal./h) | 2.7 (0.71) | |
at 1/4 Load | L/h (gal./h) | 2.2 (0.59) | |
Fuel Tank Capacity | L (gal.) | 28.0 (7.4) | |
Continous Operation Hours |
at Full Load | h | 7.0 |
at 3/4 Load | h | 8.5 | |
at 1/2 Load | h | 10.4 | |
at 1/4 Load | h | 12.7 | |
Battery (Ah/5h) | – | 55B24R (12V x 36Ah) | |
Dimensions L x W x H |
mm (in.) |
1281 x 618 x 698 (50.4 x 24.3 x 27.5) |
|
Approx. Net Weight | kg (lbs.) | 295 (650) | |
Sound Level (Full Load at 23 ft. [7m]) |
dB (A) | 68 | |
Emergency Stop System | – | In case of abnormal: oil pressure, water temperature, or when the access terminal cover is opened (terminal type only) |
Note regarding oil fill level at oil change: Here’s the update from Kubota Engines. The 722 generator on the GL11000 comes with either a 101mm or a 120mm deep oil pan. (4” or 4.75”). The 101 takes .9 gallons of oil. The 120 takes 1 gallon. If the unit has the 4.75” deep oil pan it requires 1 gallon to fill it to the top mark on the dipstick. The GL11000-USA uses dip stick part #1G304-36410.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
For the first 2 years or 2000 hours you must use factory filters, or you will void warranty. The owner’s manual recommends you change oil and oil filter first 50 hours. After that change the oil every 100 hours and the oil filter every 200 hours.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
Shipping
Shipping | This item ships to |
Delivery
Fast Shipping in the USA. Items ship the same or next day We process orders 7 days a week to ensure the fastest shipping possible. All generators are shipped as fast as possible out of several US locations to ensure the fastest delivery. |
||
Why Buy From Us
We Put Our Customers First We have done the research for you to find the best manufacturers with the best warranties. Every unit on our site is covered by a high quality manufacturers warranty. |
||
We offer the absolute lowest price we can offer |
||
We insist that you love our service. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. |
||
Ordering from AllProGenerators.com is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. |
Review
Choose Voltage and Enclosure or No Enclosure (Skid Mount)