Cummins C125D6D 125kW Agricultural Diesel Generator
Provide dependable emergency power for critical farm equipment with the Cummins C125D6D 125kW Agricultural Diesel Generator. Cummins part number A060A344 is a factory-configured agricultural standby generator designed for farms, livestock facilities, irrigation systems, poultry houses, dairy operations, grain facilities, greenhouses and other agricultural applications that rely on 120/240-volt single-phase power.
This heavy-duty diesel generator produces 125kW of standby power at 120/240V single phase and includes a 600-amp main circuit breaker. It combines a Cummins QSB7 industrial diesel engine, a brushless four-pole alternator and PowerCommand 1.1 electronic controls in an open-skid package built for demanding agricultural environments.
Important Agricultural Configuration Notice
A060A344 is an open generator set. It does not include a weather enclosure, sound enclosure or onboard diesel fuel tank. A suitable generator building or separately purchased enclosure, an external fuel system, two starting batteries, an automatic transfer switch and professional installation are required.
125kW Standby Power for Farms and Agricultural Facilities
Modern agricultural operations depend on electricity for ventilation, refrigeration, irrigation, water systems, feeding equipment, milking equipment, lighting and environmental controls. A utility outage can quickly place livestock, crops, stored products and production schedules at risk.
The Cummins C125D6D is designed to automatically provide backup power when connected to a properly selected automatic transfer switch. Its 120/240V single-phase output makes it suitable for larger farms and rural facilities with single-phase electrical service.
Key Features
- 125kW standby diesel generator
- 120/240V single-phase electrical output
- 60 Hz operating frequency
- 600-amp factory circuit breaker
- Cummins QSB7 6.69-liter diesel engine
- Heavy-duty four-cycle industrial engine design
- Turbocharged and charge-air-cooled operation
- 1,800 RPM rated engine speed
- Brushless four-pole alternator
- Low-reactance 2/3-pitch windings
- PowerCommand 1.1 electronic control system
- Automatic remote-start and stop capability
- Precise voltage and frequency regulation
- Battle Short Mode
- Flexible exercise scheduling
- Self-diagnostic capabilities
- Cooling package rated for operation up to 122°F under applicable manufacturer conditions
- Coolant heaters included for improved cold-weather starting
- Open-skid agricultural configuration
- No enclosure and no fuel tank included
Cummins QSB7 Heavy-Duty Diesel Engine
The C125D6D agricultural generator is powered by a Cummins QSB7 6.69-liter inline diesel engine. This rugged four-cycle industrial engine is engineered to provide reliable power and fast response as electrical loads change.
The cast-iron engine operates at 1,800 RPM and uses turbocharging and charge-air cooling to support dependable standby performance. A 100-amp engine-driven battery-charging alternator helps maintain the starting-battery system while the generator is operating.
Engine Features
- Cummins QSB7 industrial diesel engine
- 6.69-liter displacement
- Inline cast-iron construction
- Heavy-duty four-cycle design
- Turbocharged and charge-air cooled
- Liquid-cooled operation
- 1,800 RPM rated speed
- 100-amp battery-charging alternator
- Spin-on oil filter with pressure-relief valve
- Designed for fast response to changing loads
PowerCommand 1.1 Electronic Control System
The integrated Cummins PowerCommand 1.1 control system provides coordinated engine, alternator and generator-set management. It supports automatic operation when the generator is connected to compatible transfer equipment and provides the monitoring and protection functions required for critical standby-power applications.
PowerCommand Control Features
- Automatic remote start and stop
- Precise voltage regulation
- Precise frequency regulation
- Generator output metering
- Engine and generator status monitoring
- Alarm and operating-status messages
- Automatic shutdown when qualifying faults are detected
- Integrated generator-set protection
- Self-diagnostic capabilities
- NFPA 110 Level 1 control functionality
- Flexible generator exercise scheduling
Battle Short Mode
Battle Short Mode allows certain protective shutdowns to be overridden when maintaining power is considered more important than protecting the generator from possible damage.
This feature may be valuable in agricultural emergencies where the immediate loss of ventilation, water pumps, refrigeration, feeding systems or environmental controls could endanger livestock, crops or stored products.
Battle Short Mode must only be used by qualified personnel and in accordance with Cummins operating instructions.
Flexible Exercise Scheduling
Routine generator exercise helps confirm that the engine, alternator, controls and starting system are ready before an outage occurs. The PowerCommand control allows the exercise time, frequency and duration to be scheduled around the facility's needs.
Flexible scheduling can help reduce unnecessary noise, diesel consumption and emissions compared with a generator that exercises more often or longer than necessary.
Brushless Alternator Performance
The Cummins alternator uses a brushless, four-pole revolving-field design with low-reactance 2/3-pitch windings. This design helps provide stable voltage, low waveform distortion and the motor-starting capability needed for demanding agricultural equipment.
Alternator Features
- Brushless four-pole design
- Drip-proof revolving field
- Low-reactance 2/3-pitch windings
- Direct-coupled rotor
- Direct-drive centrifugal cooling blower
- Automatic voltage regulation
- Low waveform distortion with nonlinear loads
- Short-circuit fault-clearing capability
- Selectable motor-starting capability
Designed for Agricultural Environments
The C125D6D agricultural generator is engineered and tested for reliable operation under demanding environmental conditions. Its standard cooling package is designed for operation in ambient temperatures up to 50°C or 122°F under the applicable Cummins rating conditions.
Factory-supplied coolant heaters help support dependable starting in cold conditions when the generator is properly installed, maintained and connected to the required electrical supply.
Common Agricultural Applications
- Dairy farms and milking systems
- Poultry houses and ventilation equipment
- Livestock barns and environmental controls
- Automated feeding and watering systems
- Irrigation pumps and agricultural well systems
- Greenhouses and climate-control equipment
- Grain handling and conveyor systems
- Grain drying and storage facilities
- Produce refrigeration and cold storage
- Farm shops and equipment buildings
- Agricultural processing equipment
- Large rural properties with single-phase service
- Emergency power for critical farm infrastructure
Motor Starting and Generator Sizing
Agricultural facilities frequently use pumps, fans, compressors, augers, refrigeration equipment and other electric motors that require significantly more power during startup than during normal operation.
A generator should not be selected using running wattage alone. Proper sizing must account for motor-starting current, load sequencing, voltage drop, electrical-service configuration, elevation, ambient temperature and future equipment expansion.
A qualified generator professional or electrical engineer should complete a load and motor-starting analysis before the generator is ordered.
Open-Skid Agricultural Configuration
The Cummins A060A344 does not include an enclosure. The engine, alternator, radiator, controls and other generator components remain exposed on the open structural skid.
This generator must be installed inside a properly designed generator room, agricultural equipment building or separately purchased weather-protective enclosure. The installation must provide adequate airflow, ventilation, weather protection, exhaust routing, service clearances and protection from unauthorized access.
Do not order this model expecting a factory weather enclosure or sound-attenuated housing. Product images must be reviewed carefully because some representative Cummins images may show optional equipment or enclosed generator configurations that are not included with A060A344.
No Fuel Tank Included
A060A344 does not include an onboard, belly-mounted or sub-base diesel fuel tank. A properly sized external diesel tank or compatible separately purchased sub-base tank must be supplied as part of the installation.
The fuel-system design should account for desired runtime, fuel consumption, supply and return line sizing, maximum fuel lift, filtration, containment and all applicable fire and environmental codes.
Automatic Transfer Switch Not Included
An automatic transfer switch is not included. A properly sized transfer switch is required for automatic backup of a building or electrical service.
The transfer switch must match the facility's 120/240V single-phase service, amperage, service-entrance requirements and applicable electrical codes. Depending on the installation, a 600-amp transfer switch or a separately engineered distribution and load-management system may be required.
The generator must never be connected directly to utility-supplied wiring without approved transfer equipment.
Starting Batteries Required
The generator requires two 12-volt starting batteries rated at approximately 850 cold-cranking amps each. Starting batteries and battery cables are not included unless they are specifically listed on the final sales order.
The correct battery configuration, cable size, charger and cold-weather requirements should be confirmed during installation planning.
Product Specifications
| Manufacturer | Cummins Power Generation |
| Model | C125D6D |
| Manufacturer Part Number | A060A344 |
| Product Series | Agricultural Spec Diesel |
| Application | Agricultural standby power |
| Standby Power Rating | 125kW |
| Prime Power Rating | Not rated or marketed for prime power in this A060A344 agricultural configuration |
| Voltage | 120/240V |
| Phase | Single phase |
| Frequency | 60 Hz |
| Power Factor | 1.0 single phase |
| Approximate Full-Load Current | Approximately 521 amps at 125kW and 240V single phase |
| Main Circuit Breaker | 600 amps |
| Fuel Type | Diesel |
| Engine Manufacturer | Cummins |
| Engine Series | QSB7 |
| Engine Displacement | 6.69 liters |
| Engine Design | Heavy-duty four-cycle inline industrial diesel |
| Aspiration | Turbocharged and charge-air cooled |
| Rated Engine Speed | 1,800 RPM |
| Cooling System | Liquid cooled with high-ambient radiator package |
| Maximum Cooling-System Ambient Rating | Up to 50°C / 122°F under applicable manufacturer conditions |
| Engine Battery-Charging Alternator | 100 amps |
| Starting Battery Requirement | Two 12V batteries, approximately 850 CCA each |
| Starting Batteries Included | No |
| Generator Controller | Cummins PowerCommand 1.1 |
| Starting Method | Electric start with automatic remote-start capability |
| Alternator Design | Brushless, four-pole, drip-proof revolving field |
| Alternator Windings | Low-reactance 2/3-pitch windings |
| Exercise Function | Programmable flexible exercise mode |
| Battle Short Mode | Included |
| Enclosure | Not included — open generator set |
| Sound-Attenuated Housing | Not included |
| Fuel Tank | Not included |
| Automatic Transfer Switch | Not included |
| Mounting Configuration | Open structural skid |
| California Availability | Not for sale or use in California |
| Installation | Professional installation required |
What Is Included
- Cummins C125D6D agricultural diesel generator set
- Cummins QSB7 6.69-liter diesel engine
- 120/240V single-phase alternator
- PowerCommand 1.1 electronic control system
- 600-amp main circuit breaker
- High-ambient radiator and liquid-cooling system
- Coolant heaters
- Open structural generator skid
- Standard factory equipment associated with part number A060A344
- Cummins manufacturer documentation
What Is Not Included
- Weather-protective enclosure
- Sound-attenuated enclosure
- Integrated or sub-base diesel fuel tank
- Automatic transfer switch
- Two required 12V starting batteries
- Battery cables unless specifically listed
- Concrete generator pad or engineered foundation
- External exhaust piping and installation
- Diesel fuel lines, filtration or fuel-system installation
- Electrical wiring and installation materials
- Permits, engineering or site preparation
- Building, shelter or separately purchased enclosure
- Forklift, crane or unloading services
- Startup or commissioning unless specifically purchased
Professional Installation Required
The Cummins C125D6D must be installed by qualified generator, electrical, mechanical and fuel-system professionals. The completed installation must comply with Cummins requirements and all applicable national, state and local electrical, fire, fuel, environmental and building codes.
Installation planning should address:
- Complete electrical-load analysis
- Motor-starting requirements
- Load sequencing and load management
- Automatic transfer-switch selection
- Foundation and vibration isolation
- Weather protection for the open generator
- Combustion and radiator airflow
- Exhaust routing
- Diesel fuel storage and containment
- Grounding and electrical protection
- Starting batteries and battery charging
- Service and maintenance clearances
- Emergency shutdown requirements
Freight Shipping and Delivery
This commercial agricultural generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the generator.
A properly rated forklift, crane or other lifting equipment may be required. Do not assume that standard liftgate service will be available or sufficient for unloading this open industrial generator.
Residential delivery, farm delivery, limited-access service, jobsite delivery, storage, redelivery, appointment service, reconsignment and other special freight services may result in additional charges.
Inspect the generator and shipping materials before signing the delivery receipt. Any visible damage, missing components or packaging concerns must be clearly written on the carrier's delivery receipt at the time of delivery. Signing without noting visible damage may limit the ability to file a successful freight claim.
Cummins Limited Warranty
The Cummins C125D6D A060A344 is covered by the applicable Cummins two-year limited generator-set warranty. Warranty coverage is subject to Cummins terms, application limitations, operating-hour limits, maintenance requirements and exclusions.
The generator should be registered after installation. Authorized startup, documented maintenance and the use of approved parts and fluids may be required to preserve warranty coverage.
Refer to the Cummins limited warranty statement supplied with the generator for the complete and controlling warranty terms.
Frequently Asked Questions
Is A060A344 the agricultural version of the Cummins C125D6D?
Yes. A060A344 is a preconfigured agricultural-spec Cummins C125D6D designed to provide 125kW of standby power at 120/240V single phase.
Does this generator have an enclosure?
No. This is an open-skid generator. It does not include a weather-protective or sound-attenuated enclosure. The engine, alternator, radiator and controls are exposed and must be protected by a properly designed building or separately purchased enclosure.
Does the product image show the exact generator?
Not necessarily. Manufacturer and distributor images may be representative and may display an enclosure, fuel tank or other optional equipment. The A060A344 configuration being sold here is an open generator without an enclosure or fuel tank.
Does A060A344 include a diesel fuel tank?
No. It does not include an onboard, belly-mounted or sub-base fuel tank. A suitable external fuel tank or separately purchased compatible sub-base tank is required.
Does it include an automatic transfer switch?
No. An automatic transfer switch must be purchased separately and selected to match the facility's 120/240V single-phase electrical service and amperage.
Is this generator rated for prime power?
No. This specific A060A344 agricultural configuration is listed for standby-power applications. It should not be marketed as a prime-power generator without written confirmation from Cummins for the proposed application.
How much standby power does it produce?
The generator is rated for 125kW of standby power.
What voltage and phase does it produce?
It produces 120/240V single-phase, 60 Hz electrical power.
How many amps can it produce?
At 125kW and 240V single phase, the calculated full-load current is approximately 521 amps. The agricultural configuration includes a 600-amp circuit breaker.
What engine does the C125D6D use?
It uses a Cummins QSB7 6.69-liter industrial diesel engine operating at 1,800 RPM.
Are starting batteries included?
No. The generator requires two 12V starting batteries rated at approximately 850 cold-cranking amps each. Batteries are not included unless specifically stated on the final sales order.
Can this generator power an entire farm?
It may support a substantial portion of a farm's electrical load, but a professional load analysis is required. Large pumps, fans, compressors, refrigeration systems and augers can require several times their normal running power during startup.
Can it start an irrigation pump?
Potentially, but the answer depends on the pump horsepower, motor voltage, starting method, locked-rotor current, wiring distance and other loads operating at the same time. A motor-starting analysis should be completed before purchase.
What is PowerCommand 1.1?
PowerCommand 1.1 is the Cummins electronic generator-control system. It integrates automatic remote starting and stopping, voltage and frequency regulation, output metering, alarm messages, generator protection and self-diagnostics.
What is Battle Short Mode?
Battle Short Mode allows certain automatic protective shutdowns to be overridden when continuing to provide power is considered more important than protecting the generator from possible damage. It must only be used by qualified personnel according to Cummins instructions.
Does it exercise automatically?
Yes. The PowerCommand control provides flexible exercise scheduling so the time, duration and frequency can be programmed according to the facility's needs.
Can this open generator be installed outdoors as delivered?
No. The generator has no enclosure and should not be left exposed to rain, weather or unauthorized access. It requires a properly engineered generator building or compatible separately purchased enclosure.
Does this generator require professional installation?
Yes. Professional electrical, fuel, exhaust, mechanical and generator installation is required.
Is this generator available in California?
No. This agricultural configuration is listed as not for sale or use in California.
Important Ordering Information
Commercial generators may be factory built, configured or allocated for a specific customer order. Before ordering, confirm the following:
- Cummins part number A060A344
- 125kW standby rating
- 120/240V single-phase output
- 600-amp circuit breaker
- Open generator configuration
- No enclosure included
- No diesel fuel tank included
- No automatic transfer switch included
- No starting batteries included
- Local emissions eligibility
- Current production lead time
- Final factory-installed options
- Freight and unloading requirements
- Cancellation and return restrictions
Manufacturer: Cummins Power Generation
Model: C125D6D
Part Number: A060A344
Application: Agricultural standby power
Standby Rating: 125kW
Voltage: 120/240V
Phase: Single phase
Frequency: 60 Hz
Fuel: Diesel
Circuit Breaker: 600 amps
Configuration: Open-skid generator with no enclosure or fuel tank
Specifications, availability and standard factory equipment are subject to change. Images may show optional equipment or a representative generator configuration. The final Cummins order acknowledgment and submittal documents determine the exact equipment supplied.
```
| Shipping | This item ships to |
![]() |
Fast Shipping in the USA. Items ship the same or next day We process orders 7 days a week to ensure the fastest shipping possible. All generators are shipped as fast as possible out of several US locations to ensure the fastest delivery. |
|
![]() |
We Put Our Customers First We have done the research for you to find the best manufacturers with the best warranties. Every unit on our site is covered by a high quality manufacturers warranty. |
|
![]() |
We offer the absolute lowest price we can offer |
|
![]() |
We insist that you love our service. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. |
|
![]() |
Ordering from AllProGenerators.com is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. |
Description
Cummins C125D6D 125kW Agricultural Diesel Generator
Provide dependable emergency power for critical farm equipment with the Cummins C125D6D 125kW Agricultural Diesel Generator. Cummins part number A060A344 is a factory-configured agricultural standby generator designed for farms, livestock facilities, irrigation systems, poultry houses, dairy operations, grain facilities, greenhouses and other agricultural applications that rely on 120/240-volt single-phase power.
This heavy-duty diesel generator produces 125kW of standby power at 120/240V single phase and includes a 600-amp main circuit breaker. It combines a Cummins QSB7 industrial diesel engine, a brushless four-pole alternator and PowerCommand 1.1 electronic controls in an open-skid package built for demanding agricultural environments.
Important Agricultural Configuration Notice
A060A344 is an open generator set. It does not include a weather enclosure, sound enclosure or onboard diesel fuel tank. A suitable generator building or separately purchased enclosure, an external fuel system, two starting batteries, an automatic transfer switch and professional installation are required.
125kW Standby Power for Farms and Agricultural Facilities
Modern agricultural operations depend on electricity for ventilation, refrigeration, irrigation, water systems, feeding equipment, milking equipment, lighting and environmental controls. A utility outage can quickly place livestock, crops, stored products and production schedules at risk.
The Cummins C125D6D is designed to automatically provide backup power when connected to a properly selected automatic transfer switch. Its 120/240V single-phase output makes it suitable for larger farms and rural facilities with single-phase electrical service.
Key Features
- 125kW standby diesel generator
- 120/240V single-phase electrical output
- 60 Hz operating frequency
- 600-amp factory circuit breaker
- Cummins QSB7 6.69-liter diesel engine
- Heavy-duty four-cycle industrial engine design
- Turbocharged and charge-air-cooled operation
- 1,800 RPM rated engine speed
- Brushless four-pole alternator
- Low-reactance 2/3-pitch windings
- PowerCommand 1.1 electronic control system
- Automatic remote-start and stop capability
- Precise voltage and frequency regulation
- Battle Short Mode
- Flexible exercise scheduling
- Self-diagnostic capabilities
- Cooling package rated for operation up to 122°F under applicable manufacturer conditions
- Coolant heaters included for improved cold-weather starting
- Open-skid agricultural configuration
- No enclosure and no fuel tank included
Cummins QSB7 Heavy-Duty Diesel Engine
The C125D6D agricultural generator is powered by a Cummins QSB7 6.69-liter inline diesel engine. This rugged four-cycle industrial engine is engineered to provide reliable power and fast response as electrical loads change.
The cast-iron engine operates at 1,800 RPM and uses turbocharging and charge-air cooling to support dependable standby performance. A 100-amp engine-driven battery-charging alternator helps maintain the starting-battery system while the generator is operating.
Engine Features
- Cummins QSB7 industrial diesel engine
- 6.69-liter displacement
- Inline cast-iron construction
- Heavy-duty four-cycle design
- Turbocharged and charge-air cooled
- Liquid-cooled operation
- 1,800 RPM rated speed
- 100-amp battery-charging alternator
- Spin-on oil filter with pressure-relief valve
- Designed for fast response to changing loads
PowerCommand 1.1 Electronic Control System
The integrated Cummins PowerCommand 1.1 control system provides coordinated engine, alternator and generator-set management. It supports automatic operation when the generator is connected to compatible transfer equipment and provides the monitoring and protection functions required for critical standby-power applications.
PowerCommand Control Features
- Automatic remote start and stop
- Precise voltage regulation
- Precise frequency regulation
- Generator output metering
- Engine and generator status monitoring
- Alarm and operating-status messages
- Automatic shutdown when qualifying faults are detected
- Integrated generator-set protection
- Self-diagnostic capabilities
- NFPA 110 Level 1 control functionality
- Flexible generator exercise scheduling
Battle Short Mode
Battle Short Mode allows certain protective shutdowns to be overridden when maintaining power is considered more important than protecting the generator from possible damage.
This feature may be valuable in agricultural emergencies where the immediate loss of ventilation, water pumps, refrigeration, feeding systems or environmental controls could endanger livestock, crops or stored products.
Battle Short Mode must only be used by qualified personnel and in accordance with Cummins operating instructions.
Flexible Exercise Scheduling
Routine generator exercise helps confirm that the engine, alternator, controls and starting system are ready before an outage occurs. The PowerCommand control allows the exercise time, frequency and duration to be scheduled around the facility's needs.
Flexible scheduling can help reduce unnecessary noise, diesel consumption and emissions compared with a generator that exercises more often or longer than necessary.
Brushless Alternator Performance
The Cummins alternator uses a brushless, four-pole revolving-field design with low-reactance 2/3-pitch windings. This design helps provide stable voltage, low waveform distortion and the motor-starting capability needed for demanding agricultural equipment.
Alternator Features
- Brushless four-pole design
- Drip-proof revolving field
- Low-reactance 2/3-pitch windings
- Direct-coupled rotor
- Direct-drive centrifugal cooling blower
- Automatic voltage regulation
- Low waveform distortion with nonlinear loads
- Short-circuit fault-clearing capability
- Selectable motor-starting capability
Designed for Agricultural Environments
The C125D6D agricultural generator is engineered and tested for reliable operation under demanding environmental conditions. Its standard cooling package is designed for operation in ambient temperatures up to 50°C or 122°F under the applicable Cummins rating conditions.
Factory-supplied coolant heaters help support dependable starting in cold conditions when the generator is properly installed, maintained and connected to the required electrical supply.
Common Agricultural Applications
- Dairy farms and milking systems
- Poultry houses and ventilation equipment
- Livestock barns and environmental controls
- Automated feeding and watering systems
- Irrigation pumps and agricultural well systems
- Greenhouses and climate-control equipment
- Grain handling and conveyor systems
- Grain drying and storage facilities
- Produce refrigeration and cold storage
- Farm shops and equipment buildings
- Agricultural processing equipment
- Large rural properties with single-phase service
- Emergency power for critical farm infrastructure
Motor Starting and Generator Sizing
Agricultural facilities frequently use pumps, fans, compressors, augers, refrigeration equipment and other electric motors that require significantly more power during startup than during normal operation.
A generator should not be selected using running wattage alone. Proper sizing must account for motor-starting current, load sequencing, voltage drop, electrical-service configuration, elevation, ambient temperature and future equipment expansion.
A qualified generator professional or electrical engineer should complete a load and motor-starting analysis before the generator is ordered.
Open-Skid Agricultural Configuration
The Cummins A060A344 does not include an enclosure. The engine, alternator, radiator, controls and other generator components remain exposed on the open structural skid.
This generator must be installed inside a properly designed generator room, agricultural equipment building or separately purchased weather-protective enclosure. The installation must provide adequate airflow, ventilation, weather protection, exhaust routing, service clearances and protection from unauthorized access.
Do not order this model expecting a factory weather enclosure or sound-attenuated housing. Product images must be reviewed carefully because some representative Cummins images may show optional equipment or enclosed generator configurations that are not included with A060A344.
No Fuel Tank Included
A060A344 does not include an onboard, belly-mounted or sub-base diesel fuel tank. A properly sized external diesel tank or compatible separately purchased sub-base tank must be supplied as part of the installation.
The fuel-system design should account for desired runtime, fuel consumption, supply and return line sizing, maximum fuel lift, filtration, containment and all applicable fire and environmental codes.
Automatic Transfer Switch Not Included
An automatic transfer switch is not included. A properly sized transfer switch is required for automatic backup of a building or electrical service.
The transfer switch must match the facility's 120/240V single-phase service, amperage, service-entrance requirements and applicable electrical codes. Depending on the installation, a 600-amp transfer switch or a separately engineered distribution and load-management system may be required.
The generator must never be connected directly to utility-supplied wiring without approved transfer equipment.
Starting Batteries Required
The generator requires two 12-volt starting batteries rated at approximately 850 cold-cranking amps each. Starting batteries and battery cables are not included unless they are specifically listed on the final sales order.
The correct battery configuration, cable size, charger and cold-weather requirements should be confirmed during installation planning.
Product Specifications
| Manufacturer | Cummins Power Generation |
| Model | C125D6D |
| Manufacturer Part Number | A060A344 |
| Product Series | Agricultural Spec Diesel |
| Application | Agricultural standby power |
| Standby Power Rating | 125kW |
| Prime Power Rating | Not rated or marketed for prime power in this A060A344 agricultural configuration |
| Voltage | 120/240V |
| Phase | Single phase |
| Frequency | 60 Hz |
| Power Factor | 1.0 single phase |
| Approximate Full-Load Current | Approximately 521 amps at 125kW and 240V single phase |
| Main Circuit Breaker | 600 amps |
| Fuel Type | Diesel |
| Engine Manufacturer | Cummins |
| Engine Series | QSB7 |
| Engine Displacement | 6.69 liters |
| Engine Design | Heavy-duty four-cycle inline industrial diesel |
| Aspiration | Turbocharged and charge-air cooled |
| Rated Engine Speed | 1,800 RPM |
| Cooling System | Liquid cooled with high-ambient radiator package |
| Maximum Cooling-System Ambient Rating | Up to 50°C / 122°F under applicable manufacturer conditions |
| Engine Battery-Charging Alternator | 100 amps |
| Starting Battery Requirement | Two 12V batteries, approximately 850 CCA each |
| Starting Batteries Included | No |
| Generator Controller | Cummins PowerCommand 1.1 |
| Starting Method | Electric start with automatic remote-start capability |
| Alternator Design | Brushless, four-pole, drip-proof revolving field |
| Alternator Windings | Low-reactance 2/3-pitch windings |
| Exercise Function | Programmable flexible exercise mode |
| Battle Short Mode | Included |
| Enclosure | Not included — open generator set |
| Sound-Attenuated Housing | Not included |
| Fuel Tank | Not included |
| Automatic Transfer Switch | Not included |
| Mounting Configuration | Open structural skid |
| California Availability | Not for sale or use in California |
| Installation | Professional installation required |
What Is Included
- Cummins C125D6D agricultural diesel generator set
- Cummins QSB7 6.69-liter diesel engine
- 120/240V single-phase alternator
- PowerCommand 1.1 electronic control system
- 600-amp main circuit breaker
- High-ambient radiator and liquid-cooling system
- Coolant heaters
- Open structural generator skid
- Standard factory equipment associated with part number A060A344
- Cummins manufacturer documentation
What Is Not Included
- Weather-protective enclosure
- Sound-attenuated enclosure
- Integrated or sub-base diesel fuel tank
- Automatic transfer switch
- Two required 12V starting batteries
- Battery cables unless specifically listed
- Concrete generator pad or engineered foundation
- External exhaust piping and installation
- Diesel fuel lines, filtration or fuel-system installation
- Electrical wiring and installation materials
- Permits, engineering or site preparation
- Building, shelter or separately purchased enclosure
- Forklift, crane or unloading services
- Startup or commissioning unless specifically purchased
Professional Installation Required
The Cummins C125D6D must be installed by qualified generator, electrical, mechanical and fuel-system professionals. The completed installation must comply with Cummins requirements and all applicable national, state and local electrical, fire, fuel, environmental and building codes.
Installation planning should address:
- Complete electrical-load analysis
- Motor-starting requirements
- Load sequencing and load management
- Automatic transfer-switch selection
- Foundation and vibration isolation
- Weather protection for the open generator
- Combustion and radiator airflow
- Exhaust routing
- Diesel fuel storage and containment
- Grounding and electrical protection
- Starting batteries and battery charging
- Service and maintenance clearances
- Emergency shutdown requirements
Freight Shipping and Delivery
This commercial agricultural generator ships by freight. The customer must provide a delivery location accessible to a full-size freight carrier and arrange equipment capable of safely unloading the generator.
A properly rated forklift, crane or other lifting equipment may be required. Do not assume that standard liftgate service will be available or sufficient for unloading this open industrial generator.
Residential delivery, farm delivery, limited-access service, jobsite delivery, storage, redelivery, appointment service, reconsignment and other special freight services may result in additional charges.
Inspect the generator and shipping materials before signing the delivery receipt. Any visible damage, missing components or packaging concerns must be clearly written on the carrier's delivery receipt at the time of delivery. Signing without noting visible damage may limit the ability to file a successful freight claim.
Cummins Limited Warranty
The Cummins C125D6D A060A344 is covered by the applicable Cummins two-year limited generator-set warranty. Warranty coverage is subject to Cummins terms, application limitations, operating-hour limits, maintenance requirements and exclusions.
The generator should be registered after installation. Authorized startup, documented maintenance and the use of approved parts and fluids may be required to preserve warranty coverage.
Refer to the Cummins limited warranty statement supplied with the generator for the complete and controlling warranty terms.
Frequently Asked Questions
Is A060A344 the agricultural version of the Cummins C125D6D?
Yes. A060A344 is a preconfigured agricultural-spec Cummins C125D6D designed to provide 125kW of standby power at 120/240V single phase.
Does this generator have an enclosure?
No. This is an open-skid generator. It does not include a weather-protective or sound-attenuated enclosure. The engine, alternator, radiator and controls are exposed and must be protected by a properly designed building or separately purchased enclosure.
Does the product image show the exact generator?
Not necessarily. Manufacturer and distributor images may be representative and may display an enclosure, fuel tank or other optional equipment. The A060A344 configuration being sold here is an open generator without an enclosure or fuel tank.
Does A060A344 include a diesel fuel tank?
No. It does not include an onboard, belly-mounted or sub-base fuel tank. A suitable external fuel tank or separately purchased compatible sub-base tank is required.
Does it include an automatic transfer switch?
No. An automatic transfer switch must be purchased separately and selected to match the facility's 120/240V single-phase electrical service and amperage.
Is this generator rated for prime power?
No. This specific A060A344 agricultural configuration is listed for standby-power applications. It should not be marketed as a prime-power generator without written confirmation from Cummins for the proposed application.
How much standby power does it produce?
The generator is rated for 125kW of standby power.
What voltage and phase does it produce?
It produces 120/240V single-phase, 60 Hz electrical power.
How many amps can it produce?
At 125kW and 240V single phase, the calculated full-load current is approximately 521 amps. The agricultural configuration includes a 600-amp circuit breaker.
What engine does the C125D6D use?
It uses a Cummins QSB7 6.69-liter industrial diesel engine operating at 1,800 RPM.
Are starting batteries included?
No. The generator requires two 12V starting batteries rated at approximately 850 cold-cranking amps each. Batteries are not included unless specifically stated on the final sales order.
Can this generator power an entire farm?
It may support a substantial portion of a farm's electrical load, but a professional load analysis is required. Large pumps, fans, compressors, refrigeration systems and augers can require several times their normal running power during startup.
Can it start an irrigation pump?
Potentially, but the answer depends on the pump horsepower, motor voltage, starting method, locked-rotor current, wiring distance and other loads operating at the same time. A motor-starting analysis should be completed before purchase.
What is PowerCommand 1.1?
PowerCommand 1.1 is the Cummins electronic generator-control system. It integrates automatic remote starting and stopping, voltage and frequency regulation, output metering, alarm messages, generator protection and self-diagnostics.
What is Battle Short Mode?
Battle Short Mode allows certain automatic protective shutdowns to be overridden when continuing to provide power is considered more important than protecting the generator from possible damage. It must only be used by qualified personnel according to Cummins instructions.
Does it exercise automatically?
Yes. The PowerCommand control provides flexible exercise scheduling so the time, duration and frequency can be programmed according to the facility's needs.
Can this open generator be installed outdoors as delivered?
No. The generator has no enclosure and should not be left exposed to rain, weather or unauthorized access. It requires a properly engineered generator building or compatible separately purchased enclosure.
Does this generator require professional installation?
Yes. Professional electrical, fuel, exhaust, mechanical and generator installation is required.
Is this generator available in California?
No. This agricultural configuration is listed as not for sale or use in California.
Important Ordering Information
Commercial generators may be factory built, configured or allocated for a specific customer order. Before ordering, confirm the following:
- Cummins part number A060A344
- 125kW standby rating
- 120/240V single-phase output
- 600-amp circuit breaker
- Open generator configuration
- No enclosure included
- No diesel fuel tank included
- No automatic transfer switch included
- No starting batteries included
- Local emissions eligibility
- Current production lead time
- Final factory-installed options
- Freight and unloading requirements
- Cancellation and return restrictions
Manufacturer: Cummins Power Generation
Model: C125D6D
Part Number: A060A344
Application: Agricultural standby power
Standby Rating: 125kW
Voltage: 120/240V
Phase: Single phase
Frequency: 60 Hz
Fuel: Diesel
Circuit Breaker: 600 amps
Configuration: Open-skid generator with no enclosure or fuel tank
Specifications, availability and standard factory equipment are subject to change. Images may show optional equipment or a representative generator configuration. The final Cummins order acknowledgment and submittal documents determine the exact equipment supplied.
```
Shipping
| Shipping | This item ships to |
Delivery
![]() |
Fast Shipping in the USA. Items ship the same or next day We process orders 7 days a week to ensure the fastest shipping possible. All generators are shipped as fast as possible out of several US locations to ensure the fastest delivery. |
|
Why Buy From Us
![]() |
We Put Our Customers First We have done the research for you to find the best manufacturers with the best warranties. Every unit on our site is covered by a high quality manufacturers warranty. |
|
![]() |
We offer the absolute lowest price we can offer |
|
![]() |
We insist that you love our service. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. |
|
![]() |
Ordering from AllProGenerators.com is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. |
Review
Wildcat 10kW Renegade 3ph Tier 4F Diesel Generator
Choose Voltage and Enclosure or No Enclosure (Skid Mount)
PAGURO 4000W Marine Diesel Generator
options/Select one of the following pre-wired AC options:
EcoFlow DELTA Pro with Smart Extra Battery and 400W Solar Panel
Select Number of Solar Panels